  The electrostatic Cryogenic Storage Ring CSR – Mechanical concept and realization

Hahn, R. v., Berg, F. A., Blaum, K., Crespo López-Urrutia, J., Fellenberger, F., Froese, M., et al. (2011). The electrostatic Cryogenic Storage Ring CSR – Mechanical concept and realization. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 269(24), 2871-2874. doi:10.1016/j.nimb.2011.04.033.

Item is

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:
Keine Angabe

Urheber

einblenden:
ausblenden:
 Urheber:
Hahn, Robert von1, Autor           
Berg, Felix A.1, Autor           
Blaum, Klaus1, Autor           
Crespo López-Urrutia, Jose2, Autor           
Fellenberger, Florian1, Autor           
Froese, Michael1, Autor           
Grieser, Manfred1, Autor           
Krantz, Claude1, Autor           
Kühnel, Kai-Uwe2, Autor           
Lange, Michael1, Autor           
Menk, Sebastian1, Autor           
Laux, Felix1, Autor           
Orlov, Dmitri A.1, Autor           
Repnow, Roland1, Autor           
Schröter, Claus Dieter2, Autor           
Shornikov, Andrey1, Autor           
Sieber, Thomas1, Autor           
Ullrich, Joachim H.2, Autor           
Wolf, Andreas1, Autor           
Rappaport, M.3, Autor
Zajfman, Daniel3, Autor mehr..
Affiliations:
1Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society, ou_904548              
2Division Prof. Dr. Joachim H. Ullrich, MPI for Nuclear Physics, Max Planck Society, ou_904547              
3Weizmann Institute of Science, Rehovot, Israel, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: A new and technologically challenging project, the electrostatic Cryogenic Storage Ring CSR, is presently under construction at the Max-Planck-Institute for Nuclear Physics in Heidelberg. Applying liquid helium cooling, the CSR, with 35 m circumference, will provide a low temperature environment of only a few Kelvin and an extremely high vacuum of better than 10−13 mbar. To realize these conditions the mechanical design has been completed and now the first quarter section is in the construction phase. For the onion skin structure of the cryogenic system we have at the outer shell the cryostat chambers, realized by welded rectangular stainless steel frames with aluminum plates. The next two shells are fabricated as aluminum shields kept at 80 and 40 K. The inner vacuum chambers for the experimental vacuum consist of stainless steel chambers cladded with external copper sheets connected to the LHe lines for optimized thermal equilibration and cryopumping. Additional large surface 2 K units are installed for cryogenic pumping of H2. The mechanical concepts and the realization will be presented in detail.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2011-04-212011-12-15
 Publikationsstatus: Erschienen
 Seiten: 4
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1016/j.nimb.2011.04.033
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Amsterdam : North-Holland
Seiten: - Band / Heft: 269 (24) Artikelnummer: - Start- / Endseite: 2871 - 2874 Identifikator: ISSN: 0168-583X
CoNE: https://pure.mpg.de/cone/journals/resource/954925484704