Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Real-time MRI of speaking at a resolution of 33 ms: Undersampled radial FLASH with nonlinear inverse reconstruction.

Niebergall, A., Zhang, S., Kunay, E., Keydana, G., Job, M., Uecker, M., et al. (2013). Real-time MRI of speaking at a resolution of 33 ms: Undersampled radial FLASH with nonlinear inverse reconstruction. Magnetic Resonance in Medicine, 69(2), 477-485. doi:10.1002/mrm.24276.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
1477548.pdf (Verlagsversion), 2MB
 
Datei-Permalink:
-
Name:
1477548.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (UNKNOWN id 303; )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
1477548-SuppVideo1.avi (Ergänzendes Material), 8MB
Name:
1477548-SuppVideo1.avi
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
video/x-msvideo / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
1477548-SuppVideo2.avi (Ergänzendes Material), 15MB
Name:
1477548-SuppVideo2.avi
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
video/x-msvideo / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
1477548-SuppVideo3.avi (Ergänzendes Material), 5MB
Name:
1477548-SuppVideo3.avi
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
video/x-msvideo / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
1477548-SuppVideo4.mov (Ergänzendes Material), 3MB
Name:
1477548-SuppVideo4.mov
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
video/quicktime / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Niebergall, A.1, Autor           
Zhang, S.1, Autor           
Kunay, E., Autor
Keydana, G., Autor
Job, M., Autor
Uecker, M.1, Autor           
Frahm, J.1, Autor           
Affiliations:
1Biomedical NMR Research GmbH, MPI for biophysical chemistry, Max Planck Society, ou_578634              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Real-time MRI; speaking; articulation; tongue dynamics; speech production; phonetics
 Zusammenfassung: Dynamic MRI studies of the upper airway during speaking, singing or swallowing are complicated by the need for high temporal resolution and the presence of air-tissue interfaces that may give rise to image artifacts such as signal void and geometric distortions. This work exploits a recently developed real-time MRI technique to address these challenges for monitoring speech production at 3 T. The method combines a short-echo time radial FLASH MRI sequence (pulse repetition time/echo time = 2.22/1.44 ms; flip angle 5°) with pronounced undersampling (15 radial spokes per image) and image reconstruction by regularized nonlinear inversion. The resulting serial images at 1.5 mm in-plane resolution and 33.3 ms acquisition time are free of motion or susceptibility artifacts. This application focuses on a dynamic visualization of the main articulators during natural speech production (Standard Modern German). Respective real-time MRI movies at 30 frames per second clearly demonstrate the spatiotemporal coordination of lips, tongue, velum, and larynx for generating vowels, consonants, and coarticulations. The quantitative results for individual phonetic events are in agreement with previous non-MRI findings. Magn Reson Med, 2012. © 2012 Wiley Periodicals, Inc. Since the earliest studies of human articulation in the late 18th century, methods and applications have continuously been expanded. Nowadays, articulatory processes during speaking may be analyzed by a wide range of techniques including laryngoscopy and laryngography, electropalatography, electromyography, electromagnetic articulography, or imaging based on X-ray videofluoroscopy or sonography (1). However, while former approaches require an invasive procedure, which eventually disturbs the natural articulation of vowels and consonants, videofluoroscopy involves the exposure to radiation and sonography is restricted to specific image orientations. Although MRI promises noninvasive examinations as well as more flexible and detailed insights into the vocal tract, insufficient temporal resolution, and limited image quality still emerge as two major obstacles for studying speech production. For example, because long image acquisition times require either repetitively generated (2, 3) or continuant (4) speech sounds, such strategies preclude a proper visualization of the lips and tongue for plosive consonants that are characterized by rapid movements within 50–100 ms (5). In addition, motion-induced image blurring may result from data sharing when using long acquisitions with sliding-window reconstructions to achieve high frame rates (6, 7). It has therefore been concluded that the true temporal resolution for MRI should be comparable to that of standard videofluoroscopy, ideally no longer than 40 ms per image (8). Other problems are the occurrence of focal signal losses and geometric distortions that depend on the sensitivity of a chosen MRI acquisition technique to the unavoidable susceptibility differences near air-tissue interfaces in the upper airway (9, 10). Most recently, we have described a real-time MRI technique using highly undersampled radial FLASH with image reconstruction by regularized nonlinear inversion (11–13). Preliminary applications to cardiovascular function (14), quantitative blood flow (15), and normal swallowing (16) allow for serial real-time images (i.e., movies) with 1.5 to 2.0 mm in-plane resolution and 20–30 ms acquisition time. Accordingly, the purpose of this study was to exploit this real-time MRI method to address the challenges posed by dynamic MRI of speaking and to investigate the key articulatory configurations during natural speech production including vowels, consonants, and coarticulation effects in vowels preceded by consonants.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2012-04-122013-02
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1002/mrm.24276
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 69 (2) Artikelnummer: - Start- / Endseite: 477 - 485 Identifikator: -