  Dynamic hysteresis between gradient echo and spin echo attenuations in dynamic susceptibility contrast imaging

Xu, C., Kiselev, V. G., Möller, H. E., & Fiebach, J. E. (2013). Dynamic hysteresis between gradient echo and spin echo attenuations in dynamic susceptibility contrast imaging. Magnetic Resonance in Medicine, 69(4), 981-991. doi:10.1002/mrm.24326.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
Xu_2012_Dynamic.pdf (Preprint), 628KB
 
Datei-Permalink:
-
Name:
Xu_2012_Dynamic.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Privat
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Xu, Chao1, 2, Autor           
Kiselev, Valerij G.3, Autor
Möller, Harald E.2, Autor           
Fiebach, Jochen E.1, Autor
Affiliations:
1Academic Neuroradiology, Center for Stroke Research, Charité University Medicine Berlin, Germany, ou_persistent22              
2Methods and Development Unit Nuclear Magnetic Resonance, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634558              
3Department of Radiology, University Medical Center, Freiburg, Germany, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Dynamic susceptibility contrast; Transverse relaxation rate constant; Hysteresis; Microvasculature; Perfusion
 Zusammenfassung: Perfusion measurements using dynamic susceptibility contrast imaging provide additional information about the mean vessel size of microvasculature when supplemented with a dual gradient echo (GE) – spin echo (SE) contrast. Dynamic increase in the corresponding transverse relaxation rate constant changes, ΔR2GE and ΔR2SE, forms a loop on the (ΔRmath image, ΔR2GE) plane, rather than a reversible line. The shape of the loop and the direction of its passage differentiate between healthy brain and pathological tissue, such as tumour and ischemic tissue. By considering a tree model of microvasculature, the direction of the loop is found to be influenced mainly by the relative arterial and venous blood volume, as well as the tracer bolus dispersion. A parameter Λ is proposed to characterize the direction and shape of the loop, which might be considered as a novel imaging marker for describing the pathology of cerebrovascular network.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2012-03-092011-12-202012-04-132012-05-182013-04
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1002/mrm.24326
PMID: 22611004
Anderer: Epub 2012
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York : Wiley-Liss
Seiten: - Band / Heft: 69 (4) Artikelnummer: - Start- / Endseite: 981 - 991 Identifikator: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149