ausblenden:
Schlagwörter:
-
Zusammenfassung:
Using one arm of the Michelson interferometer and the power recycling mirror of the interferometric gravitational wave detector GEO 600, we created a Fabry-Perot cavity with a length of 1200 m. The main purpose of this experiment was to gather first experience with the main optics, its suspensions and the corresponding control systems. The residual displacement of a main mirror is about 150 nm rms. By stabilizing the length of the 1200 m long cavity to the pre-stabilized laser beam, we achieved an error point frequency noise of 100 muHz Hz(-1/2) at 100 Hz Fourier frequency. In addition we demonstrated the reliable performance of all included subsystems by several 10-hour-periods of continuous stable operation. Thus the full frequency stabilization scheme for GEO 600 was successfully tested