日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Isotropic submillimeter fMRI in the human brain at 7 T: Combining reduced field-of-view imaging and partially parallel acquisitions

Heidemann, R. M., Ivanov, D., Trampel, R., Fasano, F., Meyer, H., Pfeuffer, J., & Turner, R. (2012). Isotropic submillimeter fMRI in the human brain at 7 T: Combining reduced field-of-view imaging and partially parallel acquisitions. Magnetic Resonance in Medicine, 68(5), 1506-1516. doi:10.1002/mrm.24156.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル
非表示: ファイル
:
Heidemann_2012_Isotropic.pdf (出版社版), 2MB
 
ファイルのパーマリンク:
-
ファイル名:
Heidemann_2012_Isotropic.pdf
説明:
-
OA-Status:
閲覧制限:
非公開
MIMEタイプ / チェックサム:
application/pdf
技術的なメタデータ:
著作権日付:
-
著作権情報:
-
CCライセンス:
-

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Heidemann, Robin M.1, 著者           
Ivanov, Dimo1, 著者           
Trampel, Robert1, 著者           
Fasano, Fabrizio2, 著者
Meyer, Heiko3, 著者
Pfeuffer, Josef3, 著者
Turner, Robert1, 著者           
所属:
1Department Neurophysics, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634550              
2Department of Neuroscience, University of Parma, Italy, ou_persistent22              
3Siemens Sector Healthcare, Erlangen, Germany, ou_persistent22              

内容説明

表示:
非表示:
キーワード: Reduced field-of-view; Parallel imaging; BOLD imaging; fMRI; Outer-volume suppression; Ultrahigh field
 要旨: Echo-planar imaging is the most widely used imaging
sequence for functional magnetic resonance imaging (fMRI)
due to its fast acquisition. However, it is prone to local distortions,
image blurring, and signal voids. As these effects scale
with echo train length and field strength, it is essential for
high-resolution echo-planar imaging at ultrahigh field to
address these problems. Partially parallel acquisition methods
can be used to improve the image quality of echo-planar imaging.
However, partially parallel acquisition can be affected by
aliasing artifacts and noise enhancement. Another way to
shorten the echo train length is to reduce the field-of-view
(FOV) while maintaining the same spatial resolution. However,
to achieve significant acceleration, the resulting FOV becomes
very small. Another problem occurs when FOV selection is
incomplete such that there is remaining signal aliased from the
region outside the reduced FOV. In this article, a novel
approach, a combination of reduced FOV imaging with partially
parallel acquisition, is presented. This approach can address
the problems described above of each individual method, enabling
high-quality single-shot echo-planar imaging acquisition,
with submillimeter isotropic resolution and good signal-tonoise
ratio, for fMRI at ultrahigh field strength. This is demonstrated
in fMRI of human brain at 7T with an isotropic
resolution of 650 mm.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2011-12-162012-01-092012-10-23
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): DOI: 10.1002/mrm.24156
PMID: 22231859
その他: Epub 2012
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance in Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 68 (5) 通巻号: - 開始・終了ページ: 1506 - 1516 識別子(ISBN, ISSN, DOIなど): ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149