  Exploring the limits and losses in MALDI sample preparation of attomole amounts of peptide mixtures

Nordhoff, E., Lehrach, H., & Gobom, J. (2007). Exploring the limits and losses in MALDI sample preparation of attomole amounts of peptide mixtures. International Journal of Mass Spectrometry, 268(2-3), 139-146. doi:10.1016/j.ijms.2007.07.004.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文
その他のタイトル : Int J Mass Spectrom

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Nordhoff, Eckhard1, 著者           
Lehrach, Hans1, 著者           
Gobom, Johan1, 著者           
所属:
1Dept. of Vertebrate Genomics (Head: Hans Lehrach), Max Planck Institute for Molecular Genetics, Max Planck Society, ou_1433550              

内容説明

表示:
非表示:
キーワード: MALDI-TOF-MS; Peptide; Piezo-electric dispensing; Prestructured sample support; Detection sensitivity
 要旨: We have used a non-contact piezo-electric liquid dispensing workstation to transfer 200 pL aliquots of both a sample solution containing 12 peptides, each at a concentration of 5 or 50 fmol/μL, and dilution buffer onto microcrystalline spots of α-cyano-4-hydroxycinnamic acid for thin-layer preparations on prestructured MALDI sample supports. This approach allowed us to systematically investigate the dependence of detection sensitivity on sample volume, spot size, concentration, as well as sample losses. We demonstrate that 1 amol of the peptide mixture was sufficient to detect all components if it was prepared in a volume of 0.2 nL across a spot of ca. 180 μm diameter. If the sample was diluted on the target to 200 nL and prepared on a spot of 400 μm diameter, 10 amol could be detected and if the sample volume was increased to 1 μL, 50 amol were required to detect all components. If the peptide mixture instead was diluted in a sample vial and 1 μL of that solution was prepared on a spot of 400 μm diameter, 50 amol of the peptide mixture could be detected as well and the signal-to-noise ratios of the analyte signals were comparable to those observed for the on-target dilution experiment.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2007-12-01
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): eDoc: 335501
DOI: 10.1016/j.ijms.2007.07.004
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: International Journal of Mass Spectrometry
  出版物の別名 : Int J Mass Spectrom
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 268 (2-3) 通巻号: - 開始・終了ページ: 139 - 146 識別子(ISBN, ISSN, DOIなど): ISSN: 1387-3806