English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  3D protein microarrays: Performing multiplex immunoassays on a single chip

Angenendt, P., Glokler, J., Konthur, Z., Lehrach, H., & Cahill, D. J. (2003). 3D protein microarrays: Performing multiplex immunoassays on a single chip. Analytical Chemistry, 75(17), 4368-4372.

Item is

Basic

show hide
Genre: Journal Article
Alternative Title : Anal. Chem.

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Angenendt, Philip1, Author           
Glokler, Jörn1, Author           
Konthur, Zoltán2, Author           
Lehrach, Hans1, Author           
Cahill, Dolores J.3, Author
Affiliations:
1Dept. of Vertebrate Genomics (Head: Hans Lehrach), Max Planck Institute for Molecular Genetics, Max Planck Society, ou_1433550              
2In vitro Ligand Screening (Zoltán Konthur), Dept. of Vertebrate Genomics (Head: Hans Lehrach), Max Planck Institute for Molecular Genetics, Max Planck Society, ou_1479653              
3Max Planck Society, ou_persistent13              

Content

show
hide
Free keywords: -
 Abstract: The enzyme-linked immunosorbent assay (ELISA) is typically applied in the format of microtiter plates. To increase throughput and reduce consumption of precious samples, efforts have been made to transfer ELISA to the microchip format using conventional microarrays, microfluidic systems, and chips bearing microwells. However, all three formats lack the possibility to screen several analytes on several immobilized binders at a time or require complicated liquid handling, surface modifications, and additional equipment. Here, we describe an immunoassay performed on a standard microscope slide without the requirement for wells or tubes to separate the samples using standard surfaces and machinery already available for microarray technology. The new multiple spotting technique (MIST) comprises immobilization of a binder onto a surface and subsequent spotting of the second compound on the same spot, on top of the immobilized binder. We show that the analytes bind their ligands immediately within the confined space of separate droplets on the chip surface, thereby eliminating the need for extra incubation time. We illustrate the feasibility of the new technique by spotting dilution rows of proteins or monoclonal and polyclonal antibodies on top of their immobilized binders. Moreover, we demonstrate specificity by applying a mixture of antibodies in a multiplex format and demonstrate that the technique is compatible with conventional microarray protocols, such as total incubation. Finally, we indicate that the technique is capable of quantifying as little as 400 zmol (240 000 molecules) of analyte.

Details

show
hide
Language(s): eng - English
 Dates: 2003-09-01
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: eDoc: 126672
ISI: 000185192300011
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Analytical Chemistry
  Alternative Title : Anal. Chem.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 75 (17) Sequence Number: - Start / End Page: 4368 - 4372 Identifier: ISSN: 0003-2700