Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Protein Identification by MALDI-TOF-MS Peptide Mapping: A New Strategy

Egelhofer, V., Gobom, J., Seitz, H., Giavalisco, P., Lehrach, H., & Nordhoff, E. (2002). Protein Identification by MALDI-TOF-MS Peptide Mapping: A New Strategy. Analytical Chemistry, 74(8), 1760-1771.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Egelhofer, Volker1, Autor
Gobom, Johan2, Autor           
Seitz, Harald2, Autor           
Giavalisco, Patrick1, Autor
Lehrach, Hans2, Autor           
Nordhoff, Eckhard2, Autor           
Affiliations:
1Max Planck Society, ou_persistent13              
2Dept. of Vertebrate Genomics (Head: Hans Lehrach), Max Planck Institute for Molecular Genetics, Max Planck Society, ou_1433550              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: A new strategy for identifying proteins by MALDI-TOF-MS peptide mapping is reported. In contrast to current approaches, the strategy does not rely on a good relative or absolute mass accuracy as the criterion that discriminates false positive results. The protein sequence database is first searched for all proteins that match a minimum five of the submitted masses within the maximum expected relative errors when the default or externally determined calibration constants are used, for instance, ±500 ppm. Typically, this search retrieves many thousand candidate sequences. Assuming initially that each of these is the correct protein, the relative errors of the matching peptide masses are calculated for each candidate sequence. Linear regression analysis is then performed of the calculated relative errors as a function of m/z for each candidate sequence, and the standard deviation to the regression is used to distinguish the correct sequence among the candidates. We show that this parameter is independent of whether the mass spectrometric data were internally or externally calibrated. The result is a search engine that renders internal spectrum calibration unnecessary and adapts to the quality of the raw data without user interference. This is made possible by a dynamic scoring algorithm, which takes into account the number of matching peptide masses, the percentage of the protein's sequence covered by these peptides and, as new parameter, the determined standard deviation. The lower the standard deviation, the less cleavage peptides are required for identification and vice versa. Performance of the new strategy is demonstrated and discussed. All necessary computing has been implemented in a computer program, free access to which is provided in the Internet.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2002-03-16
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: eDoc: 24742
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Analytical Chemistry
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 74 (8) Artikelnummer: - Start- / Endseite: 1760 - 1771 Identifikator: -