Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  A 16-channel dual-row transmit array in combination with a 31-element receive array for human brain imaging at 9.4 T

Gunamony, S., Kozlov, M., Hoffmann, J., Turner, R., Scheffler, K., & Pohmann, R. (2014). A 16-channel dual-row transmit array in combination with a 31-element receive array for human brain imaging at 9.4 T. Magnetic Resonance in Medicine, 71(2), 870-879. doi:10.1002/mrm.24726.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Gunamony, Shajan1, Autor
Kozlov, Mikhail2, Autor           
Hoffmann, Jens1, Autor
Turner, Robert2, Autor           
Scheffler, Klaus1, 3, Autor
Pohmann, Rolf1, Autor
Affiliations:
1Department of High-field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Tübingen, Germany, ou_persistent22              
2Department Neurophysics, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634550              
3Department of Biomedical Magnetic Resonance, University Hospital Tübingen, Germany, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Transmit array; Receive array; 9.4 T
 Zusammenfassung: Purpose

Arranging transmit array elements in multiple rows provides an additional degree of freedom to correct B1+ field inhomogeneities and to achieve whole-brain excitation at ultrahigh field strengths. Receive arrays shaped to the contours of the anatomy increase the signal-to-noise ratio of the image. In this work, the advantages offered by the transmit and receive array techniques are combined for human brain imaging at 9.4 T.
Methods

A 16-element dual-row transmit array and a 31-element receive array were developed. Based on an accurate numerical model of the transmit array, the deposited power was calculated for different head sizes and positions. The influence of the receive array on the transmit field was characterized. Parallel imaging performance and signal-to-noise ratio of the receive array were evaluated.
Results

On average, a two fold increase in signal-to-noise ratio was observed in the whole-brain volume when compared with a 16-channel elliptic microstrip transceiver array. The benefits of combining the two arrays, B1+ shimming in three directions and high receive sensitivity, are demonstrated with high-resolution in vivo images.
Conclusion

The dual-row transmit array provides whole-brain coverage at 9.4 T, which, in combination with the helmet-shaped receive array, is a valuable radio frequency configuration for ultra-high field magnetic resonance imaging of the human brain.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2013-02-132013-03-112014-02
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1002/mrm.24726
PMID: 23483645
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 71 (2) Artikelnummer: - Start- / Endseite: 870 - 879 Identifikator: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149