English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  The water balance of northern Africa during the mid-Holocene: an evaluation of the 6 ka BP PMIP simulations

Coe, M. T., & Harrison, S. P. (2002). The water balance of northern Africa during the mid-Holocene: an evaluation of the 6 ka BP PMIP simulations. Climate Dynamics, 19(2), 155-166.

Item is

Files

show Files
hide Files
:
BGC0454.pdf (Publisher version), 216KB
 
File Permalink:
-
Name:
BGC0454.pdf
Description:
-
OA-Status:
Visibility:
Restricted (Max Planck Institute for Biogeochemistry, MJBK; )
MIME-Type / Checksum:
application/octet-stream
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Coe, M. T., Author
Harrison, S. P.1, Author           
Affiliations:
1Research Group Paleo-Climatology, Dr. S. P. Harrison, Max Planck Institute for Biogeochemistry, Max Planck Society, ou_1497765              

Content

show
hide
Free keywords: General-circulation model; land-surface processes; lake status data; late quaternary; climate model; intercomparison project; spatial variability; boundary-conditions; monsoon changes; gcm simulation
 Abstract: Runoff fields over northern Africa (10-25degreesN, 20degreesW- 30degreesE) derived from 17 atmospheric general circulation models driven by identical 6 ka BP orbital forcing, sea surface temperatures, and CO2 concentration have been analyzed using a hydrological routing scheme (HYDRA) to simulate changes in lake area. The AGCM-simulated runoff produced six-fold differences in simulated lake area between models, although even the largest simulated changes considerably underestimate the observed changes in lake area during the mid-Holocene. The inter-model differences in simulated lake area are largely due to differences in simulated runoff (the squared correlation coefficient, R-2, is 0.84). Most of these differences can be attributed to differences in the simulated precipitation (R-2 = 0.83). The higher correlation between runoff and simulated lake area (R-2 = 0.92) implies that simulated differences in evaporation have a contributory effect. When runoff is calculated using an offline land-surface scheme (BIOME3), the correlation between runoff and simulated lake area is (R-2 = 0.94). Finally, the spatial distribution of simulated precipitation can exert an important control on the overall response.

Details

show
hide
Language(s):
 Dates: 2002
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: Other: BGC0454
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Climate Dynamics
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Heidelberg : Springer-International
Pages: - Volume / Issue: 19 (2) Sequence Number: - Start / End Page: 155 - 166 Identifier: CoNE: https://pure.mpg.de/cone/journals/resource/954925568800
ISSN: 0930-7575