English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Isotopic metrology of carbon dioxide. II. Effects of ion source materials, conductance, emission, and accelerating voltage on dual-inlet cross contamination

Verkouteren, R. M., Assonov, S., Klinedinst, D. B., & Brand, W. A. (2003). Isotopic metrology of carbon dioxide. II. Effects of ion source materials, conductance, emission, and accelerating voltage on dual-inlet cross contamination. Rapid Communications in Mass Spectrometry, 17(8), 777-782.

Item is

Files

show Files
hide Files
:
BGC0659.pdf (Publisher version), 125KB
 
File Permalink:
-
Name:
BGC0659.pdf
Description:
-
OA-Status:
Visibility:
Restricted (Max Planck Institute for Biogeochemistry, MJBK; )
MIME-Type / Checksum:
application/octet-stream
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Verkouteren, R. M., Author
Assonov, S., Author
Klinedinst, D. B., Author
Brand, W. A.1, Author           
Affiliations:
1Service Facility Stable Isotope/Gas Analytics, Dr. W. A. Brand, Max Planck Institute for Biogeochemistry, Max Planck Society, ou_1497772              

Content

show
hide
Free keywords: Implantation; bombardment; beryllium; c+
 Abstract: We report high-precision isotopic carbon dioxide measurements, made before and after ion source modification to gas isotope ratio mass spectrometry (IRMS) instruments. Measurement protocols were designed to explore the effects of ion source material substitution, source conductance, inlet pressure, electron emission, acceleration potential, and inlet changeover equilibration time. After modification of the IRMS instruments at the National Institute of Standards and Technology (NIST) and the Max-Planck-Institute for Chemistry (MPI-Mainz), immediate changes were observed. At NIST, measurements were no longer sensitive to inlet equilibration times greater than 15s, and different settings of ion source conductance resulted in delta(13)C shifts of about 0.04parts per thousand per 10parts per thousand measurement difference between sample and reference, a five-fold improvement. No significant changes in machine performance were observed after a month of use. After a year, performance had degraded slightly, but was controlled by ion source cleaning and the use of low-energy ion acceleration to minimize sputtering. At MPI-Mainz, results were very similar. We report cross-contamination coefficients measured since 1996, and discuss the role of adsorption, ion implantation, and sputtering on cross contamination in mass spectrometry systems. We recommend that users of high-precision IRMS instruments test for and minimize the effects described. Published in 2003 by John Wiley Sons, Ltd.

Details

show
hide
Language(s):
 Dates: 2003
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: Other: BGC0659
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Rapid Communications in Mass Spectrometry
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York, NY : John Wiley & Sons
Pages: - Volume / Issue: 17 (8) Sequence Number: - Start / End Page: 777 - 782 Identifier: CoNE: https://pure.mpg.de/cone/journals/resource/954925574961
ISSN: 0951-4198