日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Experiments directed to the compound-specific determination of the stable carbon isotope ratios of the Toxaphene congener B8-1413 in two technical mixtures and Antarctic Weddell seal

Vetter, W., Schlatterer, J., & Gleixner, G. (2006). Experiments directed to the compound-specific determination of the stable carbon isotope ratios of the Toxaphene congener B8-1413 in two technical mixtures and Antarctic Weddell seal. Journal of Chromatography A, 1110(1-2), 165-170.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル
非表示: ファイル
:
BGC0881.pdf (出版社版), 236KB
 
ファイルのパーマリンク:
-
ファイル名:
BGC0881.pdf
説明:
-
OA-Status:
閲覧制限:
制限付き (Max Planck Institute for Biogeochemistry, MJBK; )
MIMEタイプ / チェックサム:
application/octet-stream
技術的なメタデータ:
著作権日付:
-
著作権情報:
-
CCライセンス:
-

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Vetter, W., 著者
Schlatterer, J., 著者
Gleixner, G.1, 著者           
所属:
1Molecular Biogeochemistry Group, Dr. G. Gleixner, Department Biogeochemical Processes, Prof. E.-D. Schulze, Max Planck Institute for Biogeochemistry, Max Planck Society, ou_1497773              

内容説明

表示:
非表示:
キーワード: Gc-irms Delta c-13 value 2-endo,3-exo,5-endo,6-exo,8,8,10,10-octachlorobornane b8-1413 Toxaphene 2-dimensional gas-chromatography Mass-spectrometry Melipax(r) Aroclors
 要旨: The carbon stable isotope ratio (delta C-13 value) of an environmentally-relevant Toxaphene congener in technical products and a biological sample from a remote region was in the focus of this work. For this reason, the major octachlorobornane residue of the multicomponent pesticide Toxaphene in biological samples, 2-endo,3-exo,5-endo,6-exo,8,8,10,10-octachlorobornane (B8-1413 or P26), was quantitatively enriched from two technical Toxaphene mixtures (Toxaphene and Melipax) in duplicates as well as from an Antarctic Weddell seal sample. Normal phase followed by reversed-phase high-performance liquid chromatography (HPLC) with three columns, respectively, coupled in series was used for this purpose. Four of the five fractionated samples fulfilled the requirement of an interference-free GC-elution for subsequent determination of the delta C-13 value by gas chromatography interfaced to an isotope ratio mass spectrometer (GC-IRMS). B8-1413 in Toxaphene (n = 1) was more depleted in C-12 than in Melipax (n = 2), which agrees with previous results obtained for the entire mixtures. The B8-1413 isolate from a Weddell seal sample from the Antarctic showed a 8 degrees C value between the two technical products. Although a source appointment to the one or the other product was not possible, this example indicates that long range transport to the Antarctic and by uptake and food-chain bioaccumulation of B8-1413 in seals did not change the delta C-13 value significantly. The observed differences in one duplicate sample indicate that statistic evaluation of samples used for isotope ratio MS measurements is an important issue. (c) 2006 Elsevier B.V. All rights reserved. [References: 24]

資料詳細

表示:
非表示:
言語:
 日付: 2006
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): その他: BGC0881
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Journal of Chromatography A
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Amsterdam : Elsevier
ページ: - 巻号: 1110 (1-2) 通巻号: - 開始・終了ページ: 165 - 170 識別子(ISBN, ISSN, DOIなど): CoNE: https://pure.mpg.de/cone/journals/resource/954925527837_1
ISSN: 0021-9673