English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Small-mass graphite preparation by sealed tube zinc reduction method for AMS 14C measurements

Khosh, M. S., Xu, X. M., & Trumbore, S. E. (2010). Small-mass graphite preparation by sealed tube zinc reduction method for AMS 14C measurements. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 268(7-8), 927-930. doi:10.1016/j.nimb.2009.10.066.

Item is

Files

show Files
hide Files
:
BEX494.pdf (Publisher version), 476KB
 
File Permalink:
-
Name:
BEX494.pdf
Description:
-
OA-Status:
Visibility:
Restricted (Max Planck Institute for Biogeochemistry, MJBK; )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Khosh, M. S., Author
Xu, X. M., Author
Trumbore, S. E.1, Author           
Affiliations:
1External Organizations, ou_persistent22              

Content

show
hide
Free keywords: C-14 AMS Graphitization Zinc reduction ion-source development facility
 Abstract: Previous work has demonstrated that the sealed tube Zn reduction method for converting CO2 to graphite for AMS C-14 measurements produces targets that can be measured with high precision and low background for samples of about 1 mg C down to approximately 0.1 mg C at the Keck Carbon Cycle AMS facility at the University of California, Irvine (KCCAMS). Now a modified method has been developed to prepare small-mass samples ranging from 0.015 to 0.1 mg C. In this modified method, the volume of the sealed reactor tube is reduced to similar to 1.9 cm(3), and the amounts of Zn and TiH2 reagents are reduced proportionally. The amount of Fe catalyst used remains the same to ensure a long lasting current in the AMS. Small-mass samples prepared by this method generally yield C-12(+1) currents of about 0.5 mu A per 1 mu g C. An in situ simultaneous AMS delta C-13 measurement allows for correction of both graphitization and machine-induced isotopic fractionation, and is a prerequisite for high precision and accurate measurements using the Zn reducing method. Corrections for modern-carbon and dead-carbon background components are applied to samples based on small-mass samples of a C-14 free material and of a modern standard covering the sample size range. It was discovered during additional investigation into lowering the modern-carbon background component that baking assembled reactor tubes at 300 degrees C for 1 h prior to use resulted in significantly lower modern-carbon background values. The accuracy and precision of small-mass samples prepared by this method are size dependent, but is usually +/-10-15%. for the smallest samples (0.015-0.02 mg C), based on duplicate measurements of primary and secondary standards. (C) 2009 Elsevier B.V. All rights reserved.

Details

show
hide
Language(s): eng - English
 Dates: 2010
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1016/j.nimb.2009.10.066
ISI: ://000277462300062
Other: BEX494
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
  Abbreviation : NIM B
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Amsterdam : Elsevier B.V.
Pages: - Volume / Issue: 268 (7-8) Sequence Number: - Start / End Page: 927 - 930 Identifier: ISSN: 0168-583X
CoNE: https://pure.mpg.de/cone/journals/resource/954925484704