English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Validation of routine continuous airborne CO2 observations near the Bialystok Tall Tower

Chen, H., Winderlich, J., Gerbig, C., Katrynski, K., Jordan, A., & Heimann, M. (2012). Validation of routine continuous airborne CO2 observations near the Bialystok Tall Tower. Atmospheric Measurement Techniques, 5(4), 873-889. doi:10.5194/amt-5-873-2012.

Item is

Files

show Files
hide Files
:
BGC1578.pdf (Publisher version), 616KB
Name:
BGC1578.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/octet-stream / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
:
BGC1578D.pdf (Publisher version), 765KB
Name:
BGC1578D.pdf
Description:
Discussion paper
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/octet-stream / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-

Locators

show
hide
Locator:
http://dx.doi.org/10.5194/amt-5-873-2012 (Publisher version)
Description:
OA
OA-Status:

Creators

show
hide
 Creators:
Chen, H.1, Author           
Winderlich, J.2, Author           
Gerbig, C.2, Author           
Katrynski, K., Author
Jordan, Armin3, Author           
Heimann, M.1, Author           
Affiliations:
1Department Biogeochemical Systems, Prof. M. Heimann, Max Planck Institute for Biogeochemistry, Max Planck Society, ou_1497755              
2Airborne Trace Gas Measurements and Mesoscale Modelling, Dr. habil. C. Gerbig, Department Biogeochemical Systems, Prof. M. Heimann, Max Planck Institute for Biogeochemistry, Max Planck Society, ou_1497784              
3Service Facility Gas Analytical Laboratory, Dr. A. Jordan, Max Planck Institute for Biogeochemistry, Max Planck Society, ou_2068299              

Content

show
hide
Free keywords: -
 Abstract: Since 2002 in situ airborne measurements of atmospheric CO2 mixing ratios have been performed regularly aboard a rental aircraft near Bialystok (53°08' N, 23°09' E), a city in northeastern Poland. Since August 2008, the in situ CO2 measurements have been made by a modified commercially available and fully automated non-dispersive infrared (NDIR) analyzer system. The response of the analyzer has been characterized and the CO2 mixing ratio stability of the associated calibration system has been fully tested, which results in an optimal calibration strategy and allows for an accuracy of the CO2 measurements within 0.2 ppm. Besides the in situ measurements, air samples have been collected in glass flasks and analyzed in the laboratory for mixing ratios of CO2, CO, CH4, N2O, H2, SF6 and for isotopic ratios of δ13C and δ18O in CO2. To validate the in situ CO2 measurements against reliable discrete flask measurements, we developed weighting functions that mimic the temporal averaging of the flask sampling process. Comparisons between in situ and flask CO2 measurements demonstrate that these weighting functions can compensate for atmospheric variability, and provide an effective method for validating airborne in situ CO2 measurements. In addition, we show the nine-year records of flask CO2 measurements, from which the CO2 increase rates are computed for the 300 m level (1.59 ± 0.21 ppm yr−1) and for the 2500 m level (1.77 ± 0.08 ppm yr−1). The new system, automated since August 2008, has eliminated the need for manual in-flight calibrations, and thus enables an additional vertical profile, 20 km away, to be sampled at no additional cost in terms of flight hours. This sampling strategy provides an opportunity to investigate both temporal and spatial variability on a regular basis.

Details

show
hide
Language(s):
 Dates: 2012-04-062012-04-272012
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.5194/amt-5-873-2012
Other: BGC1578
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Atmospheric Measurement Techniques
  Abbreviation : AMT
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Göttingen : European Geosciences Union, Copernicus
Pages: - Volume / Issue: 5 (4) Sequence Number: - Start / End Page: 873 - 889 Identifier: ISSN: 1867-1381
CoNE: https://pure.mpg.de/cone/journals/resource/1867-1381