日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Recombinant protein purification using gradient-assisted simulated moving bed hydrophobic interaction chromatography. Part I: Selection of chromatographic system and estimation of adsorption isotherms

Palani, S., Gueorguieva, L., Rinas, U., Seidel-Morgenstern, A., & Jayaraman, G. (2011). Recombinant protein purification using gradient-assisted simulated moving bed hydrophobic interaction chromatography. Part I: Selection of chromatographic system and estimation of adsorption isotherms. Journal of Chromatography A, 1218(37), 6396-6401. doi:10.1016/j.chroma.2011.06.111.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Palani, S.1, 2, 著者           
Gueorguieva, L.3, 著者           
Rinas, U.4, 5, 著者
Seidel-Morgenstern, A.1, 3, 著者           
Jayaraman, G.2, 著者
所属:
1Physical and Chemical Foundations of Process Engineering, Max Planck Institute for Dynamics of Complex Technical Systems, Max Planck Society, ou_1738150              
2Indian Institute of Technology-Madras, Dep. of Biotechnology, Chennai, India, persistent:22              
3Otto-von-Guericke-Universität Magdeburg, External Organizations, ou_1738156              
4Helmholtz Centre for Infection Research, Braunschweig, Germany, ou_persistent22              
5Leibniz University of Hanover, Institute of Technical Chemistry–Life Science, Hannover, Germany, ou_persistent22              

内容説明

表示:
非表示:
キーワード: Perturbation method; Adsorption isotherm parameters; Simulated moving bed; Hydrophobic interaction chromatography; Recombinant streptokinase
 要旨: The design of gradient simulated moving bed (SMB) chromatographic processes requires after selection of the chromatographic system the determination of adsorption isotherm parameters in the relevant range of mobile phase conditions. The determination of these parameters can be quite difficult for recombinant target proteins present in complex protein mixtures. The first part of this work includes the estimation of adsorption isotherm parameters for streptokinase and a lumped impurity fraction present in an E.coli cell lysate for a hydrophobic interaction chromatography (HIC) matrix. Perturbation experiments were carried out using a Butyl Sepharose matrix with purified recombinant protein on buffer equilibrated columns as well as with crude cell lysate saturated columns. The Henry constants estimated for streptokinase were found to exhibit in a wide range a linear dependence on the salt concentration in the mobile phase. These parameters were applied in subsequent investigations to design a simulated moving bed (SMB) process capable to purify in a continuous manner recombinant streptokinase from the E.coli cell lysate. Copyright © 2011 Published by Elsevier B.V. [accessed September 1st 2011]

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2011
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): eDoc: 570417
DOI: 10.1016/j.chroma.2011.06.111
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Journal of Chromatography A
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Amsterdam : Elsevier
ページ: - 巻号: 1218 (37) 通巻号: - 開始・終了ページ: 6396 - 6401 識別子(ISBN, ISSN, DOIなど): ISSN: 0021-9673
CoNE: https://pure.mpg.de/cone/journals/resource/954925527837_1