  Nonlinear frequency response method for estimation of single solute adsorption isotherms. Part II: Experimental study

Ilic, M., Petkovska, M., & Seidel-Morgenstern, A. (2007). Nonlinear frequency response method for estimation of single solute adsorption isotherms. Part II: Experimental study. Chemical Engineering Science, 62(16), 4394-4408. doi:10.1016/j.ces.2007.05.005.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Ilic, M.1, Autor           
Petkovska, M.2, Autor
Seidel-Morgenstern, A.1, 3, Autor           
Affiliations:
1Physical and Chemical Foundations of Process Engineering, Max Planck Institute for Dynamics of Complex Technical Systems, Max Planck Society, ou_1738150              
2University of Belgrade, Department of Chemical Engineering, Faculty of Technology and Metallurgy, Belgrade, Serbia, ou_persistent22              
3Otto-von-Guericke-Universität Magdeburg, External Organizations, ou_1738156              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Adsorption isotherms; Liquid chromatography; Nonlinear frequency response; Harmonic analysis; Higher-order frequency response functions; Parameter estimation
 Zusammenfassung: The aim of this paper is to investigate the possibility of applying a nonlinear frequency response method described by Ilić et al. (2007b) to determine single solute adsorption isotherms. The method is based on the analysis of the nonlinear frequency response of a chromatographic column to a periodical change of the inlet concentration around several steady-state concentrations. The first, second and third local derivatives of single solute isotherms are estimated from the low frequency asymptotic behaviour of the corresponding frequency response functions. The adsorption of 4-tert-butylphenol and ethyl benzoate as single solutes is studied on octadecyl silica (C18) from methanol-water mixture (60:40). Experiments are performed using a standard gradient HPLC unit capable to realize inlet concentration changes in a nearly sine waveform. Small injections of compounds into the not preloaded column, as well as conventional frontal analysis experiments are performed for rough estimation of the adsorption isotherm coefficients and comparison with the results obtained using the nonlinear frequency response method. Copyright © 2007 Elsevier Ltd. All rights reserved. [accessed 2013 November 26th]

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2007
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: eDoc: 298322
Anderer: 11/07 b
DOI: 10.1016/j.ces.2007.05.005
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Chemical Engineering Science
  Andere : Chem. Eng. Sci.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Amsterdam : Pergamon
Seiten: - Band / Heft: 62 (16) Artikelnummer: - Start- / Endseite: 4394 - 4408 Identifikator: ISSN: 0009-2509
CoNE: https://pure.mpg.de/cone/journals/resource/954925389239