Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Theoretical study of multicomponent continuous countercurrent chromatography based on connected 4-zone units

Keßler, L. C., & Seidel-Morgenstern, A. (2006). Theoretical study of multicomponent continuous countercurrent chromatography based on connected 4-zone units. Journal of Chromatography A, 1126(1-2), 323-337. doi:10.1016/j.chroma.2006.05.012.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Keßler, L. C.1, Autor           
Seidel-Morgenstern, A.1, 2, Autor           
Affiliations:
1Physical and Chemical Foundations of Process Engineering, Max Planck Institute for Dynamics of Complex Technical Systems, Max Planck Society, ou_1738150              
2Otto-von-Guericke-Universität Magdeburg, External Organizations, ou_1738156              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Continuous countercurrent or simulated moving bed (SMB) chromatography is a well-established separation technology. Conventional processes are based on four zones which fulfil distinct functions in order to split a feed into two fractions. Frequently there is an interest in isolating a target component out of a feed mixture containing more than two components. Modifications of the classical SMB process are required to solve this task. In the last years several concepts exploiting more than four zones have been suggested. To analyse these concepts the equilibrium theory has been frequently applied, neglecting all kinetic effects. It is the purpose of this paper to apply an equilibrium stage model in order to describe the performance of a combination of two or three 4-zone true moving bed units which are connected in series or integrated into 8- or 12-zone true moving bed units. The performance of such units is evaluated with respect to their potential to continuously separate ternary or quaternary mixtures. The analysis is based on the assumption of linear adsorption isotherms. An important aspect is the introduction of additional purge streams required for a successful operation of integrated 8- and 12-zone units. 2006 Elsevier Inc. All rights reserved [accessed 2013 November 27th]

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2006
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: eDoc: 286998
Anderer: 16/06
DOI: 10.1016/j.chroma.2006.05.012
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of Chromatography A
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Amsterdam : Elsevier
Seiten: - Band / Heft: 1126 (1-2) Artikelnummer: - Start- / Endseite: 323 - 337 Identifikator: ISSN: 0021-9673
CoNE: https://pure.mpg.de/cone/journals/resource/954925527837_1