日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Tangential Flow Filtration of Influenza Virus as a Model System

Kalbfuss, B., Zimmermann, A., Wickramasinghe, B., Morenweiser, R., & Reichl, U. (2005). Tangential Flow Filtration of Influenza Virus as a Model System. Poster presented at Engineering with Membranes, Camogli, Italy.

Item is

基本情報

表示: 非表示:
資料種別: ポスター

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Kalbfuss, B.1, 著者           
Zimmermann, A.1, 著者           
Wickramasinghe, B.2, 著者
Morenweiser, R.2, 著者
Reichl, U.1, 3, 著者           
所属:
1Bioprocess Engineering, Max Planck Institute for Dynamics of Complex Technical Systems, Max Planck Society, ou_1738140              
2Fast Trak Services Europe, Amersham Biosciences Europe GmbH, Germany Department of Chemical Engineering, Colorado State University, United States, ou_persistent22              
3Otto-von-Guericke-Universität Magdeburg, ou_1738156              

内容説明

表示:
非表示:
キーワード: -
 要旨: Background: Purification of virus particles for vaccines and viral vectors for gene therapy is a major large-scale separations challenge. Here we consider the purification of human influenza virus as a model system for enveloped viruses of about 100 nm in diameter. Methods: Virus produced in roller bottles (250 mL per bottle) and microcarrier cultures (2-3 L wv) was clarified by two static filtration steps and inactivated with ß-propiolactone. The use of tangential flow filtration and dialfiltration was investigated in order to concentrate the virus and to reduce the level of contaminating compounds. Small-scale hollow-fibre modules (40..200 cm2 filter area, Amersham Biosciences) with different molecular weight cut-offs and pore sizes (500 kDa, 750 kDa, 0.1 µm, 0.45 µm) were used in this study. Rejection of virus particles, permeation of protein and DNA, permeate flux and flux decline were examined for all the membranes. Results: No virus was found in the permeates of the 500 kDa and 750 kDa membranes whereas complete breakthrough was achieved with the 0.45 µm membrane. Virus particles seemed to enter the pores of the 0.1 µm membrane leading to very low recoveries. Most of the contaminating proteins could be removed by diafiltration using a 750 kDa membrane. Only partial removal of DNA could be achieved independent of the membrane type. Conclusion: 750 kDa hollow-fibre membranes seem to be an ideal choice for the concentration of influenza virus. They resulted in high recoveries of the product whereas most of the contaminating proteins could be removed. The partial removal of DNA suggests that genomic DNA fragments are either about the same size as or ar

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2005
 出版の状態: 不明
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): eDoc: 240030
 学位: -

関連イベント

表示:
非表示:
イベント名: Engineering with Membranes
開催地: Camogli, Italy
開始日・終了日: 2005-05-22 - 2005-05-25

訴訟

表示:

Project information

表示:

出版物

表示: