  Electrocardiogram-triggered, higher order, projection-based B0 shimming allows for fast and reproducible shim convergence in spinal cord 1H MRS

Hock, A., Fuchs, A., Boesiger, P., Kollias, S., & Henning, A. (2013). Electrocardiogram-triggered, higher order, projection-based B0 shimming allows for fast and reproducible shim convergence in spinal cord 1H MRS. NMR in Biomedicine, 26(3), 329-335. doi:10.1002/nbm.2852.

Item is

Basisdaten

ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

ausblenden:
externe Referenz:
http://onlinelibrary.wiley.com/doi/10.1002/nbm.2852/pdf (Verlagsversion)
Beschreibung:
-
OA-Status:

Urheber

ausblenden:
 Urheber:
Hock, A, Autor
Fuchs, A, Autor
Boesiger, P, Autor
Kollias, SS, Autor
Henning, A1, Autor           
Affiliations:
1University and ETH Zurich , ou_persistent22              

Inhalt

ausblenden:
Schlagwörter: -
 Zusammenfassung: 1H MRS allows insight into the chemical composition of the central nervous system. However, as a result of technical challenges, it has rarely been applied to the spinal cord. In particular, the strong susceptibility changes around the spinal cord and the pulsatile flow of the cerebrospinal fluid lead to distinct B0 field distortions which often considerably degrade the spectral quality. Hence, B0 shimming is one of the main challenges in 1H MRS of the spinal cord. Electrocardiogram (ECG)-triggered, higher order, projection-based B0 shimming was introduced and compared with both conventional projection-based B0 shimming and B0 shimming based on ECG-triggered, three-dimensional B0 field mapping. The linewidth of the unsuppressed water peak was used to evaluate the reproducibility and the potential improvement to B0 homogeneity. The use of ECG-triggered projection-based B0 shimming in combination with ECG triggering during preparation phases and triggering during acquisition of the spectra is the most robust method and thus helps to improve the spectral quality for MRS of the spinal cord.

Details

ausblenden:
Sprache(n):
 Datum: 2013-03
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1002/nbm.2852
BibTex Citekey: HockFBKH2013
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

ausblenden:
Titel: NMR in Biomedicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 26 (3) Artikelnummer: - Start- / Endseite: 329 - 335 Identifikator: -