English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Overdiscrete Reconstruction for Highly Accelerated Parallel 1H MRSI at 7T with Efficient Control of Voxel Bleeding

Kirchner, T., Fillmer, A., Boesiger, P., Pruessmann, K., & Henning, A. (2012). Overdiscrete Reconstruction for Highly Accelerated Parallel 1H MRSI at 7T with Efficient Control of Voxel Bleeding. Magnetic Resonance Materials in Physics, Biology and Medicine, 25(Supplement 1), 298-299.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Kirchner, T, Author
Fillmer, A, Author
Boesiger, P, Author
Pruessmann, KP, Author
Henning, A1, Author           
Affiliations:
1Institute for Biomedical Engineering, University and ETH Zürich, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: Purpose/Introduction: MRSI suffers from the voxel bleeding effect, where the spectrum in a given voxel exhibits contributions from other spatial regions. Intra-voxel variation of coil element sensitivities, especially at ultra-high fields, may cause significant additional contamination in parallel MRSI [1,2,3,4]. We extend the SENSE technique by introducing spatial overdiscretization and combining it with direct optimization of the Spatial Response Function (SRF) [5,6,7] to reduce residual aliasing and suppress SRF side lobes. Subjects and Methods: A 20x16 voxel 1H FIDLOVS [8] MRSI was acquired at 7T with a 16channel receive array from a transversal slice of a healthy volunteer’s brain with coil sensitivity information. The reconstruction operator F for voxel π is calculated from the encoding matrix E by minimizing the cost function Δπ=||(FE – T)π||22 + α(FΨFH)πwhere the regularization parameter α weights SRF optimization (first term) against noise minimization (second term) and T contains the SRF target functions [5,7]. E and T are newly sampled at multiple positions per voxel (overdiscretization). Results: SRF side lobes reflecting voxel bleeding into the voxel of interest abound at a simulated R=4-fold acceleration (Fig. 1). For R=9, even residual aliasing peaks are discernible. With a slightly widened Gaussian SRF target (width σ=1.5 in units of the underlying spatial grid) and threefold overdiscretization, very efficient side lobe and aliasing peak suppression are combined with an acceptably small increase of the effective voxel size. Minimal noise regularization is desired for SRF shape and unfolding but causes numerical ill-conditioning. We find, in our example, α=1 to be a good compromise (Fig. 2). Spatio-spectral quality improves drastically over standard SENSE (Fig. 3, 4). Even with the inherent SNR decrease, acceptable spectra are obtained at R=9, which corresponds to an acquisition time of only 4.5 min. Discussion/Conclusion: We demonstrate up to 9-fold accelerated FIDLOVS MRSI at 7T with intrinsic and efficient suppression of voxel bleeding contributions as well as good maintenance of the nominal spatial resolution in contrast to conventional k-space apodization methods.

Details

show
hide
Language(s):
 Dates: 2012-10
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1007/s10334-012-0323-x
BibTex Citekey: KirchnerFBPH2012
 Degree: -

Event

show
hide
Title: 29th Annual Scientific Meeting ESMRMB 2012
Place of Event: Lisboa, Portugal
Start-/End Date: -

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance Materials in Physics, Biology and Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 25 (Supplement 1) Sequence Number: - Start / End Page: 298 - 299 Identifier: -