  Evaluation of a new, large field of view, small animal PET/MR system

Hossain, M., Wehrl, H., Lankes, K., Liu, C., Bezrukov, I., Reischl, G., et al. (2012). Evaluation of a new, large field of view, small animal PET/MR system. Talk presented at 50. Jahrestagung der Deutschen Gesellschaft fuer Nuklearmedizin (NuklearMedizin 2012). Bremen, Germany.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Hossain, M, Autor
Wehrl, HF, Autor
Lankes, K, Autor
Liu, C, Autor
Bezrukov, Ilya1, Autor           
Reischl, G, Autor
Pichler, BJ, Autor
Affiliations:
1Universität Tübingen, Department für Präklinische Bildgebung und Radiopharmazie, Tübingen, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Ziel/Aim: Combined PET/MR imaging is an evolving field in small animal as well as human medical imaging. Our group successfully constructed a second generation small animal PET-insert, which allows for large field of view PET/ MR imaging. Here we present technical details about the new PET-insert as well as an evaluation of its PET and MR performance. Methodik/Methods: The new PET-insert uses a total of 16 circularly arranged, copper shielded, detector cassettes. Each cassette consists of 3 avalanche photodiode (APD) arrays, each attached to a 15x15 LSO crystal block (single crystal size 1.5x1.5x10mm). The PET-insert is air cooled via vortex tubes and a temperature feedback system to an operating temperature of 15°C. The PETinsert is mounted inside a 7T small animal MR system. The total PET/MR field of view with installed whole body MR coils is ca. 72x70mm, allowing for whole body mouse as well as rat imaging. The PET spatial resolution was evaluated for different reconstruction algorithms, using a glass capillary tube, filled with 1MBq of F-18-FDG solution. Furthermore the sensitivity of the PET-insert was measured via a small glass sphere filled with 340kBq of F-18 in an energy window of 350keV-650keV. On the MR side the signal to noise ratio (SNR) as well as image homogeneity was measured for different MR sequences (n=18). In vivo images of a rat heart were also obtained. Ergebnisse/Results: The PET spatial resolution for an OSEM reconstruction (16 iterations) was found to be (2.22±0.06)mm without an MR sequence running, and (2.19±0.05)mm with an EPI MR sequence applied. The sensitivity at the center FOV of the PET insert was (3.19±0.22)% without and (3.1±0.08)% with the MR sequence. Neither spatial resolution nor sensitivity of the PET changed significantly when an MR EPI sequence was applied. The MR SNR with the PET insert varied, depending on the used MR sequence, between 25 for turbospinecho and 8 for flash sequences. Only for the TSE sequence a small, but significant (p<0.05) drop of the SNR (without PET: 24.9±0.3 with PET: 24.4±0.3) on the order of 2% was observed. The other sequences showed no significant influence of the PET on the MR performance. In vivo images of a rat heart revealed, that gated acquisitions of PET and MR data were simultaneously possible with this setup. The high quality images allowed identification of the heart ventricles. Schlussfolgerungen/Conclusions: Our data clearly shows that the next generation of small animal PET/MR systems is able to perform on par with stand alone solutions. Small fluctuations of the SNR with the PET insert installed are in the range of the typical experimental variability for small animal studies. The in vivo imaging data reveals the huge potential of this technique in preclinical and clinical research.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2012-04
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: BibTex Citekey: HossainWLLBRP2012
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 50. Jahrestagung der Deutschen Gesellschaft fuer Nuklearmedizin (NuklearMedizin 2012)
Veranstaltungsort: Bremen, Germany
Start-/Enddatum: -

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Nuklearmedizin
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 51 (2) Artikelnummer: V10 Start- / Endseite: A8 - A8 Identifikator: -