  Evaluation and Optimization of MR-Based Attenuation Correction Methods in Combined Brain PET/MR

Mantlik, F., Hofmann, M., Bezrukov, I., Schmidt, H., Kolb, A., Beyer, T., et al. (2011). Evaluation and Optimization of MR-Based Attenuation Correction Methods in Combined Brain PET/MR. Poster presented at 2011 IEEE Nuclear Science Symposium, Medical Imaging Conference (NSS-MIC 2011), Valencia, Spain.

Item is

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Mantlik, F1, Autor           
Hofmann, M1, Autor           
Bezrukov, I1, Autor           
Schmidt, H, Autor
Kolb, A, Autor
Beyer, T, Autor
Reimold, M, Autor
Schölkopf, B1, Autor           
Pichler, BJ, Autor
Affiliations:
1Dept. Empirical Inference, Max Planck Institute for Intelligent Systems, Max Planck Society, ou_1497647              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Combined PET/MR provides simultaneous molecular and functional information in an anatomical context with unique soft tissue contrast. However, PET/MR does not support direct derivation of attenuation maps of objects and tissues within the measured PET field-of-view. Valid attenuation maps are required for quantitative PET imaging, specifically for scientific brain studies. Therefore, several methods have been proposed for MR-based attenuation correction (MR-AC). Last year, we performed an evaluation of different MR-AC methods, including simple MR thresholding, atlas- and machine learning-based MR-AC. CT-based AC served as gold standard reference. RoIs from 2 anatomic brain atlases with different levels of detail were used for evaluation of correction accuracy. We now extend our evaluation of different MR-AC methods by using an enlarged dataset of 23 patients from the integrated BrainPET/MR (Siemens Healthcare). Further, we analyze options for improving the MR-AC performance in terms of speed and accuracy. Finally, we assess the impact of ignoring BrainPET positioning aids during the course of MR-AC. This extended study confirms the overall prediction accuracy evaluation results of the first evaluation in a larger patient population. Removing datasets affected by metal artifacts from the Atlas-Patch database helped to improve prediction accuracy, although the size of the database was reduced by one half. Significant improvement in prediction speed can be gained at a cost of only slightly reduced accuracy, while further optimizations are still possible.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2011-10
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: BibTex Citekey: MantlikHBSKBRSP2011
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 2011 IEEE Nuclear Science Symposium, Medical Imaging Conference (NSS-MIC 2011)
Veranstaltungsort: Valencia, Spain
Start-/Enddatum: 2011-10-23 - 2011-10-29

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: 2011 IEEE Nuclear Science Symposium, Medical Imaging Conference (NSS-MIC 2011)
Genre der Quelle: Konferenzband
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: - Artikelnummer: MIC18.M-96 Start- / Endseite: - Identifikator: -