  Comparison of biomechanical properties between acupuncture and non-penetrating sham needle

Chae, Y., Um, S.-I., Yi, S.-H., Lee, H., Chang, D.-S., Yin, C., et al. (2011). Comparison of biomechanical properties between acupuncture and non-penetrating sham needle. Complementary Therapies in Medicine, 19(Supplement 1), S8-S12. doi:10.1016/j.ctim.2010.09.002.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Chae, Y, Autor
Um, S-I, Autor
Yi, S-H, Autor
Lee, H, Autor
Chang, D-S1, Autor           
Yin, CS, Autor
Park, H-J, Autor
Affiliations:
1Acupuncture and Meridian Science Research Center, Kyung Hee University, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Objectives A non-penetrating sham needle has been considered as a reliable control treatment in the field of acupuncture research. However, some concerns with regard to the credibility of sham needles have also been raised. We investigated whether there were differences in biomechanical properties and acupuncture sensation ratings in the process of needling between verum acupuncture (VA) and sham acupuncture (SA). Methods To quantify biomechanical force during needling in a cross-over design, we used a computer-controlled needling system. Fourteen participants received VA or SA at acupuncture point LI4, with no visual impact. They were asked to complete an acupuncture sensation form, including penetration, acute pain and DeQi sensations, and to identify the needling type they received. Results We found that there was a significant difference in insertion force between VA and SA (68.5 ± 12.2 vs. 27.2 ± 3.9 gf; p < 0.001). Participants clearly distinguished between the two kinds of stimulation and rated higher sensory ratings in the VA session (penetration sensation: 4.9 ± 3.1 vs. 1.7 ± 2.3, acute pain: 4.9 ± 2.7 vs. 1.9 ± 2.6, respectively; p < 0.01). Conclusions Our findings demonstrate that differential biomechanical forces such as insertion and pullout force contribute to the sensation of real and non-penetrating sham needles.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2011-01
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1016/j.ctim.2010.09.002
BibTex Citekey: ChaeUYLCYP2011
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Complementary Therapies in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 19 (Supplement 1) Artikelnummer: - Start- / Endseite: S8 - S12 Identifikator: -