English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Comparison of biomechanical properties between acupuncture and non-penetrating sham needle

Chae, Y., Um, S.-I., Yi, S.-H., Lee, H., Chang, D.-S., Yin, C., et al. (2011). Comparison of biomechanical properties between acupuncture and non-penetrating sham needle. Complementary Therapies in Medicine, 19(Supplement 1), S8-S12. doi:10.1016/j.ctim.2010.09.002.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Chae, Y, Author
Um, S-I, Author
Yi, S-H, Author
Lee, H, Author
Chang, D-S1, Author           
Yin, CS, Author
Park, H-J, Author
Affiliations:
1Acupuncture and Meridian Science Research Center, Kyung Hee University, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: Objectives A non-penetrating sham needle has been considered as a reliable control treatment in the field of acupuncture research. However, some concerns with regard to the credibility of sham needles have also been raised. We investigated whether there were differences in biomechanical properties and acupuncture sensation ratings in the process of needling between verum acupuncture (VA) and sham acupuncture (SA). Methods To quantify biomechanical force during needling in a cross-over design, we used a computer-controlled needling system. Fourteen participants received VA or SA at acupuncture point LI4, with no visual impact. They were asked to complete an acupuncture sensation form, including penetration, acute pain and DeQi sensations, and to identify the needling type they received. Results We found that there was a significant difference in insertion force between VA and SA (68.5 ± 12.2 vs. 27.2 ± 3.9 gf; p < 0.001). Participants clearly distinguished between the two kinds of stimulation and rated higher sensory ratings in the VA session (penetration sensation: 4.9 ± 3.1 vs. 1.7 ± 2.3, acute pain: 4.9 ± 2.7 vs. 1.9 ± 2.6, respectively; p < 0.01). Conclusions Our findings demonstrate that differential biomechanical forces such as insertion and pullout force contribute to the sensation of real and non-penetrating sham needles.

Details

show
hide
Language(s):
 Dates: 2011-01
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1016/j.ctim.2010.09.002
BibTex Citekey: ChaeUYLCYP2011
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Complementary Therapies in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 19 (Supplement 1) Sequence Number: - Start / End Page: S8 - S12 Identifier: -