  Position-Position Control with Gain-Scheduling for Telesurgical Systems

Cho, J., Son, H., Bhattacharjee, T., Lee, D., & Lee, D. (2010). Position-Position Control with Gain-Scheduling for Telesurgical Systems. In International Conference on Advanced Mechatronics: Toward Evolutionary Fusion of IT and Mechatronics (ICAM 2010) (pp. 283-288). Tokyo, Japan: Japan Society of Mechanical Engineers.

Item is

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Cho, JH, Autor
Son, HI1, 2, Autor           
Bhattacharjee , T, Autor
Lee, DG, Autor
Lee, DY, Autor
Affiliations:
1Department Human Perception, Cognition and Action, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497797              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Surgical teleoperation systems are being increasingly deployed. There are, however, remaining issues such as nonlinear characteristics of the interaction between the
slave robot and soft tissues, and difficulty in employing
force sensors in the surgical end-effectors of the slave.
These issues make it difficult to offer a general
approach to designing the overall control structure.
This paper addresses these issues by proposing an
optimized controller which guarantees robust stability
and performance. The environment, i.e., soft tissues, is
characterized with the nonlinear Hunt-Crossley model.
The overall teleoperation system is modeled as a linear
parameter-varying system. A gain-scheduling control
scheme is adapted to design a performance-optimized
controller while guaranteeing robust stability. The
developed gain-scheduling control scheme shows good
tracking capacity and high transparency in varied
experimental conditions. Error of the transmitted
impedance is significantly lower compared to other
conventional control schemes for frequency band less
than 2 Hz which is frequently recommended for
surgical teleoperation.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2010-10
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: BibTex Citekey: 6655
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: International Conference on Advanced Mechatronics : Toward Evolutionary Fusion of IT and Mechatronics (ICAM 2010)
Veranstaltungsort: Osaka, Japan
Start-/Enddatum: 2010-10-04 - 2010-10-06

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: International Conference on Advanced Mechatronics : Toward Evolutionary Fusion of IT and Mechatronics (ICAM 2010)
Genre der Quelle: Konferenzband
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Tokyo, Japan : Japan Society of Mechanical Engineers
Seiten: - Band / Heft: - Artikelnummer: - Start- / Endseite: 283 - 288 Identifikator: -