English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Cerebral Venous Thrombosis: Diagnostic Accuracy of Combined, Dynamic and Static, Contrast-Enhanced 4D MR Venography

Meckel, S., Reisinger, C., Bremerich, J., Damm, D., Wolbers, M., Engelter, S., et al. (2010). Cerebral Venous Thrombosis: Diagnostic Accuracy of Combined, Dynamic and Static, Contrast-Enhanced 4D MR Venography. AJNR American Journal of Neuroradiology, 31(3), 527-535. doi:10.3174/ajnr.A1869.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Meckel, S, Author
Reisinger, C, Author
Bremerich , J, Author
Damm, D, Author
Wolbers , M, Author
Engelter, S, Author
Scheffler, K1, Author           
Wetzel, SG, Author
Affiliations:
1External Organizations, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: BACKGROUND AND PURPOSE:
MR including MRV is an established method to diagnose CVT. However, it remains unsettled which MR imaging modalities offer the highest diagnostic accuracy. We evaluated the accuracy of a combined, dynamic (1.5 seconds per dataset) and static (voxel size, 1.1 x 0.9 x 1.5 mm), contrast-enhanced MRV method (combo-4D MRV) relative to other established MR/MRV modalities.
MATERIALS AND METHODS:
A total of 39 patients with CVT (n = 20) and control subjects (n = 19) underwent combo-4D MRV, 2D TOF MRV, GRE imaging, and T2W imaging. For these modalities, diagnostic accuracy (ROCs) for CVT affecting 53 out of 234 predefined venous segments was determined. Sensitivity and specificity were separately calculated for different stages of CVT (acute/subacute/chronic).
RESULTS:
Combo-4D MRV showed the highest accuracy (AUC, 0.99 [95 CI, 0.97-1.0]; sensitivity, 97 [84-100]) for thrombosed dural sinuses. For all thrombosed segments including cortical veins, its sensitivity was best (76 [64-84]; AUC, 0.92 [0.88-0.96]), followed by TOF MRV (72 [59-81]; AUC, 0.93 [0.88-0.97]). Even for chronic CVT, it showed a relatively high sensitivity of 67 (30-90). For thrombosed cortical veins alone, GRE images achieved the highest sensitivity (66 [46-81]; AUC, 0.88 [0.78-0.97]). Specificities of all modalities ranged from 96 to 99.
CONCLUSIONS:
Combo-4D MRV showed an excellent accuracy for the diagnosis of dural sinus thrombosis. The analysis of dynamic patterns of contrast enhancement in dural sinuses appeared useful to identify chronic thrombosis. To diagnose thrombosed cortical veins, GRE images should primarily be analyzed.

Details

show
hide
Language(s):
 Dates: 2010-03
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.3174/ajnr.A1869
BibTex Citekey: MeckelRBDWESW2010
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: AJNR American Journal of Neuroradiology
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 31 (3) Sequence Number: - Start / End Page: 527 - 535 Identifier: -