  A Microstrip Resonator for Animal MRI at 16.4T

Shajan, G., Balla, D., Hoffmann, J., & Pohmann, R. (2008). A Microstrip Resonator for Animal MRI at 16.4T. Poster presented at ESMRMB 2008 Congress: 25th Annual Meeting, Valencia, Spain.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Shajan, G1, 2, Author           
Balla, DZ1, 2, Author           
Hoffmann, J1, 2, Author           
Pohmann, R1, 2, Author           
Affiliations:
1Former Department MRZ, Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_2528700              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: Introduction: MRI is increasingly moving towards higher magnetic field because
of the inherent high sensitivity and greater spectroscopic resolution.
To realize these advantages, the front end, the RF coil and the receive chain,
needs to be optimized. A Quadrature Microstrip Transmission Line (MTL)
resonator was built and SNR is compared with a commercially available
shielded linear birdcage coil. This work also includes development of a TR
switch module (consisting of T/R switch and preamplifier) and a Microstrip
transmission line based Quadrature hybrid.
Subjects and Methods: Experiments were performed on a 16.4T/26cm horizontal
bore Magnex Magnet attached to a Bruker biospec Spectrometer. The
imaging gradient system has an inner diameter of 12cms.
The resonator (Figure 1) is built on Teflon cylinder with wall thickness 5mm.
It consists of 8 equally spaced λ/2 MTL resonators. Electromagnetic coupling
among the 8 resonators makes the entire MTL volume coil resonate at the
desired frequency. In this case, each resonator is tuned to 725MHz to resonate
the volume coil to 705MHz in the unloaded condition.
The TR switch module consists of a diode network and a 2 stage low noise
amplifier (LNA). The first stage of the LNA has PHEMT ATF35143 and the
second stage has BJT BFR193. The TR switch module has a gain of 30dB and
noise figure of 1.1dB at 698MHz.
Results: The losses in the receive chain is reduced by connecting the TR
switch module closer to the birdcage coil. An SNR gain of 1.4X is observed as
shown in Table 1. The MTL resonator has double the volume of the birdcage
resonator and has comparable SNR as that of the birdcage resonator (Table
1). The linear and combined phantom images are shown in Figure 2. Figure
3 shows in-vivo Axial and Sagittal rat brain RARE images with in-plane spatial
resolution of 117μm.
Conclusion: A Quadrature MTL resonator with good SNR and signal uniformity
has been built. This paves the way for developing actively decoupled
resonators and to use smaller receive only surface coils for improved
Sensitivity at 16.4T.

Details

show
hide
Language(s):
 Dates: 2008-10
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1007/s10334-008-0126-2
BibTex Citekey: 5335
 Degree: -

Event

show
hide
Title: ESMRMB 2008 Congress: 25th Annual Meeting
Place of Event: Valencia, Spain
Start-/End Date: 2008-10-02 - 2008-10-04

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance Materials in Physics, Biology and Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Amsterdam : No longer published by Elsevier
Pages: - Volume / Issue: 21 (Supplement 1) Sequence Number: 912 Start / End Page: 449 - 450 Identifier: ISSN: 0968-5243
CoNE: https://pure.mpg.de/cone/journals/resource/954926245532