日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  fMRI of the temporal lobe of the awake monkey at 7 T

Goense, J., Ku, S.-P., Merkle, H., Tolias, A., & Logothetis, N. (2008). fMRI of the temporal lobe of the awake monkey at 7 T. NeuroImage, 39(3), 1081-1093. doi:10.1016/j.neuroimage.2007.09.038.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

作成者

表示:
非表示:
 作成者:
Goense, JBM1, 2, 著者           
Ku, S-P1, 2, 著者           
Merkle, H, 著者           
Tolias, AS1, 2, 著者           
Logothetis, NK1, 2, 著者           
所属:
1Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497798              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

内容説明

表示:
非表示:
キーワード: -
 要旨: Increasingly 7 T scanners are used for fMRI of humans and non-human primates, promising improvements in signal-to-noise, spatial resolution and specificity. A disadvantage of fMRI at 7 T, but already at 3 T, is that susceptibility artifacts from air-filled cavities like the ear canal and nasal cavity cause signal loss and distortion. This limits the applicability of fMRI in these areas, thereby limiting study of these areas, but it also limits study of processes that span large-scale cortical networks or the entire brain. Our goal is to study the inferior temporal (IT) lobe in awake monkeys because of its importance in object perception and recognition, but the functional signal is degraded by strong susceptibility gradients. To allow fMRI of this region, we used an optimized SE-EPI, which recovers signal lost with GE-EPI and we corrected for susceptibility-induced image distortion. SE-EPI has the added advantage that, in contrast to GE-EPI, where the functional signal derives to a large extent from veins, th
e SE-EPI signal arises from the microvasculature, and hence it better represents the neural activation. We show fMRI at 7 T of the entire visual pathway in the awake primate with robust and widespread activation in all ventral areas of the brain, including areas adjacent to the ear canal. This allows fMRI of areas that normally suffer from artifact and thus more reliable whole-brain studies.

資料詳細

表示:
非表示:
言語:
 日付: 2008-02
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1016/j.neuroimage.2007.09.038
BibTex参照ID: 4824
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: NeuroImage
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Orlando, FL : Academic Press
ページ: - 巻号: 39 (3) 通巻号: - 開始・終了ページ: 1081 - 1093 識別子(ISBN, ISSN, DOIなど): ISSN: 1053-8119
CoNE: https://pure.mpg.de/cone/journals/resource/954922650166