日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Quantification of Cerebral Blood Flow in Nonhuman Primates Using Arterial Spin Labeling and a Two-Compartment Model

Zappe, A.-C., Reichold, J., Burger C, Weber, B., Buck A, Pfeuffer, J., & Logothetis, N. (2007). Quantification of Cerebral Blood Flow in Nonhuman Primates Using Arterial Spin Labeling and a Two-Compartment Model. Magnetic Resonance Imaging, 25(6), 775-783. doi:10.1016/j.mri.2006.11.028.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Zappe, A-C1, 著者           
Reichold, J1, 著者           
Burger C, Weber, B1, 著者           
Buck A, Pfeuffer, J1, 著者           
Logothetis, NK1, 著者           
所属:
1Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497798              

内容説明

表示:
非表示:
キーワード: -
 要旨: Noninvasive absolute quantification of cerebral blood flow (CBF) with high spatial resolution is still a challenging task. Arterial spin labeling (ASL) is a promising magnetic resonance imaging (MRI) method for accurate perfusion quantification. However, modeling of ASL data is far from being standardized and has not been investigated in great detail. In this study, two-compartment modeling of monkey ASL data in three physiological conditions (baseline, sensory activated and globally elevated CBF) is reported. Absolute perfusion and arterial transit times were derived for gray matter (GM) and white matter (WM) separately. The uncertainties of the modelamp;amp;lsquo;s result were determined by Monte Carlo simulations. The fitted CBF values for GM were 133 ml/min/100 ml at baseline condition, 165 ml/min/100 ml during visual stimulation and 234 ml/min/100 ml for globally elevated CBF after intravenous injection of acetazolamide. The ratio of GM to WM CBF was 2.5 at baseline and was found to d ecre ase to 1 .6 after application of acetazolamide. The corresponding arterial transit times decreased from 742 to 607 ms in GM and from 985 to 875 ms in WM. Monte Carlo simulations showed that absolute CBF values can be determined with an error of 11–15, while the arterial transit time values have a coefficient of variation of 25–31. With an alternative acquisition scheme, the precision of the arterial transit times can be improved significantly. The CBF values in the occipital lobe of the monkey brain quantified with ASL are higher than previously reported in positron emission tomography studies.

資料詳細

表示:
非表示:
言語:
 日付: 2007-07
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance Imaging
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 25 (6) 通巻号: - 開始・終了ページ: 775 - 783 識別子(ISBN, ISSN, DOIなど): -