English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  MR Angiography of Dural Arteriovenous Fistulas: Diagnosis and Follow-Up after Treatment Using a Time-Resolved 3D Contrast-Enhanced Technique

Meckel, S., Maier, M., San Millan, R., Yilmaz, H., Scheffler, K., Radü, E.-W., et al. (2007). MR Angiography of Dural Arteriovenous Fistulas: Diagnosis and Follow-Up after Treatment Using a Time-Resolved 3D Contrast-Enhanced Technique. American Journal of Neuroradiology, 28(5), 877-884.

Item is

Files

show Files

Locators

show
hide
Locator:
http://www.ajnr.org/content/28/5/877.long (Publisher version)
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Meckel, S, Author
Maier, M, Author
San Millan , RD, Author
Yilmaz, H, Author
Scheffler, K1, Author           
Radü, E-W, Author
Wetzel, SG, Author
Affiliations:
1External Organizations, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: BACKGROUND AND PURPOSE: Digital subtraction angiography (DSA) is the method of reference for imaging of dural arteriovenous fistula (DAVF). The goal of this study was to analyze the value of different MR images including 3D contrast-enhanced MR angiography (MRA) with a high temporal resolution in diagnostic and follow-up imaging of DAVFs.
MATERIALS AND METHODS: A total of 18 MR/MRA examinations from 14 patients with untreated (n = 9) and/or treated (n = 9) DAVFs were evaluated. Two observers assessed all MR and MRA investigations for signs indicating the presence of a DAVF, for fistula characteristics such as fistula grading, location of fistulous point, and fistula obliteration after treatment. All results were compared with DSA findings.
RESULTS: On time-resolved 3D contrast-enhanced (TR 3D) MRA, the side and presence of all patent fistulas (n = 13) were correctly indicated, and no false-positive findings were observed in occluded DAVFs (n = 5). Grading of fistulas with this imaging technique was correct in 77 and 85 of patent fistulas for both readers, respectively. On T2-weighted images, signs indicative of a DAVF were encountered only in fistulas with cortical venous reflux (56), whereas on 3D time-of-flight (TOF) MRA, most fistulas (88) were correctly detected. In complete fistula occlusion, false-positive findings were encountered on both T2-weighted images and on TOF MRA images.
CONCLUSION: In this study, TR 3D MRA proved reliable in detecting DAVFs and suitable for follow-up imaging. The technique allowed—within limitations—to grade DAVFs. Although 3D TOF MRA can depict signs of DAVFs, its value for follow-up imaging is limited.

Details

show
hide
Language(s):
 Dates: 2007-05
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: BibTex Citekey: MeckelMSYSRW2007
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: American Journal of Neuroradiology
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Baltimore : Williams & Wilkins Co.
Pages: - Volume / Issue: 28 (5) Sequence Number: - Start / End Page: 877 - 884 Identifier: ISSN: 0195-6108
CoNE: https://pure.mpg.de/cone/journals/resource/954925490872