Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Using SE-EPI to Measure Visual Responses in the Awake Macaque at 7 Tesla

Ku, S.-P., Goense, J., Tolias, A., & Logothetis, N. (2007). Using SE-EPI to Measure Visual Responses in the Awake Macaque at 7 Tesla. Poster presented at 7th Meeting of the German Neuroscience Society, 31st Göttingen Neurobiology Conference, Göttingen, Germany.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Ku, S-P1, 2, Autor           
Goense, J1, 2, Autor           
Tolias, A1, 2, Autor           
Logothetis, NK1, 2, Autor           
Affiliations:
1Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497798              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: In contrast to electrophysiological studies, the advantage of fMRI is that it allows simultaneous mapping of the functional organization of multiple cortical areas. FMRI of awake monkey has benefit of combining
behavioral studies with BOLD-measurement to be used to precisely localize functional specific cortical areas for further invasive studies such as detailed electrophysiological single unit recordings. Although high
magnetic field offers the benefit of increased signal-to-noise ratios and higher specificity, a drawback is the higher sensitivity to susceptibility gradients caused by the air-tissue interfaces. This can be particularly
problematic in the lower floor of temporal lobe because the large macroscopic susceptibility gradients near the ear canal result in distortion and loss of signal when the standard GE-EPI is used. For fMRI of such areas using spin-echo EPI (SE-EPI) is advantageous because it is less sensitive than GE-EPI to susceptibility artifacts, and does not suffer from signal dropout in these regions. Another advantage is that SE-EPI is less affected by frequency-changes in the main magnetic field, which are caused by movement of the animal. In this study, we compared SE-EPI and gradient-echo fMRI in the awake monkey (Macaca mulatta), using a vertical bore 7T MR system. A saddle coil optimized for temporal cortex was used to allow imaging of the major visual areas. The imaging parameters and slice orientation were optimized to minimize susceptibility
effects. Resolution was typically 1.5x2x2mm, TE was 40 ms, TR was 1-2 s. In contrast to the GE-EPI images, which showed very large signal dropout in the temporal lobe, SE images showed minimal or no distortion or signal losses. Any remaining distortions were corrected using field-map correction to ensure perfect matching of the functional map to the high-resolution T1-weighted anatomical images. Using movie- stimuli, we confirmed that reliable functional activation could be obtained with SE-EPI at high field, and we show robust activation in the temporal lobe and early visual areas. Using random-dot kinematograms of various coherences
we were also able to obtain functional activities in specific visual motion sensitive areas such as MT, MST and an area located within the lower bank of superior temporal sulcus by contract of high coherence (80)
and zero-coherence random dot stimuli. The reliability and specificity of the obtained activations with SE-EPI ensures the application of the method in our on-going visual perception studies.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2007-02
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: BibTex Citekey: KuGTL2007
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 7th Meeting of the German Neuroscience Society, 31st Göttingen Neurobiology Conference
Veranstaltungsort: Göttingen, Germany
Start-/Enddatum: 2007-03-29 - 2007-04-01

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Neuroforum
Genre der Quelle: Zeitschrift
 Urheber:
Hoffmann, K-P, Herausgeber
Krieglstein, K, Herausgeber
Affiliations:
-
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 13 (Supplement) Artikelnummer: T17-5C Start- / Endseite: 765 Identifikator: ISSN: 0947-0875
CoNE: https://pure.mpg.de/cone/journals/resource/110978984249776