Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Reduced field-of-view MRI using outer volume suppression for spinal cord diffusion imaging

Wilm, B., Svensson, J., Henning, A., Pruessmann, K., Boesiger, P., & Kollias, S. (2007). Reduced field-of-view MRI using outer volume suppression for spinal cord diffusion imaging. Magnetic Resonance in Medicine, 57(3), 625-630. doi:10.1002/mrm.21167.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Wilm, BJ, Autor
Svensson, J, Autor
Henning, Anke1, Autor           
Pruessmann, KP, Autor
Boesiger, P, Autor
Kollias, SS, Autor
Affiliations:
1Institute of Biomedical Engineering, University and ETH Zurich, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: A spin-echo single-shot echo-planar imaging (SS-EPI) technique with a reduced field of view (FOV) in the phase-encoding direction is presented that simultaneously reduces susceptibility effects and motion artifacts in diffusion-weighted (DW) imaging (DWI) of the spinal cord at a high field strength (3T). To minimize aliasing, an outer volume suppression (OVS) sequence was implemented. Effective fat suppression was achieved with the use of a slice-selection gradient-reversal technique. The OVS was optimized by numerical simulations with respect to T1 relaxation times and B1 variations. The optimized sequence was evaluated in vitro and in vivo. In simulations the optimized OVS showed suppression to <0.25 and ∼3 in an optimal and worst-case scenario, respectively. In vitro measurements showed a mean residual signal of <0.95 ± 0.42 for all suppressed areas. In vivo acquisition with 0.9 × 1.05 mm2 in-plane resolution resulted in artifact-free images. The short imaging time of this technique makes it promising for clinical studies.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2007-03
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1002/mrm.21167
BibTex Citekey: WilmSHPBK2007
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 57 (3) Artikelnummer: - Start- / Endseite: 625 - 630 Identifikator: -