  Perfusion-based functional imaging in the monkey brain at 7T: investigations of CASL parameters

Zappe, A., Merkle, H., Pfeuffer, J., & Logothetis, N. (2006). Perfusion-based functional imaging in the monkey brain at 7T: investigations of CASL parameters. Poster presented at 14th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM 2006), Seattle, WA, USA.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
ISMRM-2006-Zappe.pdf (beliebiger Volltext), 145KB
Name:
ISMRM-2006-Zappe.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
https://cds.ismrm.org/ismrm-2006/files/program.pdf (Zusammenfassung)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Zappe, A1, 2, Autor           
Merkle, H, Autor           
Pfeuffer, J1, 2, Autor           
Logothetis, NK1, 2, Autor           
Affiliations:
1Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497798              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Perfusion-based imaging in the monkey primary visual cortex was performed at 7 T applying continuous arterial spin labeling (CASL). Increased perfusion sensitivity and SNR at high magnetic field (due to larger T1) was further optimized using a custom-made three-coil setup with a separate neck labeling coil. We investigated the labeling parameters to obtain relative fCBF changes in the anaesthetized monkey. We report excellent functional activation of striate cortex at high resolution of 0.75x0.9mm2 in-plane. Interestingly, the optimal parameter set for obtaining highest signal changes of rCBF are different from the reported values for imaging gray matter CBF.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2006-05
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: BibTex Citekey: 3970
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 14th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM 2006)
Veranstaltungsort: Seattle, WA, USA
Start-/Enddatum: 2006-05-06 - 2006-05-12

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: 14th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM 2006)
Genre der Quelle: Konferenzband
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: - Artikelnummer: 2135 Start- / Endseite: 419 Identifikator: -