English
 
User Manual Privacy Policy Disclaimer Contact us
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  m-Alternative-Forced-Choice: Improving the Efficiency of the Method of Constant Stimuli

Jäkel, F., Hill, J., & Wichmann, F. (2004). m-Alternative-Forced-Choice: Improving the Efficiency of the Method of Constant Stimuli. Poster presented at 7th Tübingen Perception Conference (TWK 2004), Tübingen, Germany.

Item is

Basic

show hide
Item Permalink: http://hdl.handle.net/11858/00-001M-0000-0013-D9FB-A Version Permalink: http://hdl.handle.net/21.11116/0000-0005-65EF-D
Genre: Poster

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Jäkel, F1, 2, Author              
Hill, J1, 2, Author              
Wichmann, FA1, 2, Author              
Affiliations:
1Department Empirical Inference, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497795              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: We explored several ways to improve the efficiency of measuring psychometric functions without resorting to adaptive procedures. a) The number m of alternatives in an m-alternative-forced-choice (m-AFC) task improves the efficiency of the method of constant stimuli. b) When alternatives are presented simultaneously on different positions on a screen rather than sequentially time can be saved and memory load for the subject can be reduced. c) A touch-screen can further help to make the experimental procedure more intuitive. We tested these ideas in the measurement of contrast sensitivity and compared them to results obtained by sequential presentation in two-interval-forced-choice (2-IFC). Qualitatively all methods (m-AFC and 2-IFC) recovered the characterictic shape of the contrast sensitivity function in three subjects. The m-AFC paradigm only took about 60 of the time of the 2-IFC task. We tried m=2,4,8 and found 4-AFC to give the best model fits and 2-AFC to have the least bias.

Details

show
hide
Language(s):
 Dates: 2004-02
 Publication Status: Published in print
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: BibTex Citekey: 2637
 Degree: -

Event

show
hide
Title: 7th Tübingen Perception Conference (TWK 2004)
Place of Event: Tübingen, Germany
Start-/End Date: 2004-01-30 - 2004-02-01

Legal Case

show

Project information

show

Source 1

show
hide
Title: 7th Tübingen Perception Conference: TWK 2004
Source Genre: Proceedings
 Creator(s):
Bülthoff, HH1, Editor            
Mallot, HA, Editor            
Ulrich, RD, Editor
Wichmann, FA1, Editor            
Affiliations:
1 Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794            
Publ. Info: Kirchentellinsfurt, Germany : Knirsch
Pages: - Volume / Issue: - Sequence Number: - Start / End Page: 118 Identifier: ISBN: 3-927091-68-5