日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Conventional MRA and contrast- enhanced MRA of extracranial vessel segments

Boos, M., Scheffler, K., Ott, H., Radü, E., & Bongartz, G. (1997). Conventional MRA and contrast- enhanced MRA of extracranial vessel segments. Der Radiologe, 37(7), 515-528. doi:10.1007/s001170050249.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Boos, M, 著者
Scheffler, K1, 著者           
Ott, HW, 著者
Radü, EW, 著者
Bongartz, G, 著者
所属:
1External Organizations, ou_persistent22              

内容説明

表示:
非表示:
キーワード: -
 要旨: The introduction of fast gradient systems allows a reliable visualization of the extracranial carotid vessels by the magnetic resonance angiography (MRA) which meanwhile is implemented into clinical routine. By the mainly applied time-of-flight (TOF) technique, vessels can be imaged without contrast agent (CA). Due to the application of ultra-fast gradient-echo-sequences, the first-pass evaluation of an intravenous bolus-injection of Gadolinium in the carotids from the aortic arch up to the skull base can be performed in less than 30 s. In this study, advantages and disadvantages of both techniques are discussed. For a qualitatively optimal contrast enhanced MRA (CE-MRA) timing parameters like injection delay, flow rate and the adjustment of sequence parameters have to be considered in relation to the fast venous return from the sinus to the jugular veins. First, the optimal time point of the data acquisition have been determined at a model and with a computer simulation in reference to the presence of CA in the arteries. As a result, 90 of the contrast contribution is defined by 16 of the symmetrically acquired central k-space lines. A measuring protocol for clinical use was obtained by a gradual variation of spacial resolution, measuring time and CA-injection parameters and was proved in normal volunteers and patients. An exact determination of the bolus-arrival-time by means of a test-bolus injection was acquired. The best qualitative results were achieved by a double-dose injection at 2 ml/s injection rate. The temporal reserves of ultra-fast sequences should be invested in the improvement of the spatial resolution. To date, further investigations related to the problem of optimal CA-application may improve the potentials of CE-MRA procedures.

資料詳細

表示:
非表示:
言語:
 日付: 1997-08
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1007/s001170050249
BibTex参照ID: BoosSORB1997
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Der Radiologe
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Berlin : Springer-Verlag.
ページ: - 巻号: 37 (7) 通巻号: - 開始・終了ページ: 515 - 528 識別子(ISBN, ISSN, DOIなど): ISSN: 0033-832X
CoNE: https://pure.mpg.de/cone/journals/resource/954925437500