Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Enhanced accuracy of kinetic information from CT-CPMG experiments by transverse rotating-frame spectroscopy.

Ban, D., Mazur, A., Giao Carneiro, M., Sabo, T. M., Giller, K., Koharudin, L. M. I., et al. (2013). Enhanced accuracy of kinetic information from CT-CPMG experiments by transverse rotating-frame spectroscopy. Journal of Biomolecular NMR, 57(1), 73-82. doi:10.1007/s10858-013-9769-.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
1836786.pdf (Verlagsversion), 656KB
Name:
1836786.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Ban, D.1, Autor           
Mazur, A.1, Autor           
Giao Carneiro, M.1, Autor           
Sabo, T. M.1, Autor           
Giller, K.1, Autor           
Koharudin, L. M. I., Autor
Becker, S.1, Autor           
Gronenborn, A. M., Autor
Griesinger, C.1, Autor                 
Lee, D.1, Autor           
Affiliations:
1Department of NMR-based Structural Biology, MPI for biophysical chemistry, Max Planck Society, ou_578567              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Relaxation dispersion; CT-CPMG; R-1 rho; Kinetics
 Zusammenfassung: Micro-to-millisecond motions of proteins transmit pivotal signals for protein function. A powerful technique for the measurement of these motions is nuclear magnetic resonance spectroscopy. One of the most widely used methodologies for this purpose is the constant-time Carr-Purcell-Meiboom-Gill (CT-CPMG) relaxation dispersion experiment where kinetic and structural information can be obtained at atomic resolution. Extraction of accurate kinetics determined from CT-CPMG data requires refocusing frequencies that are much larger than the nuclei's exchange rate between states. We investigated the effect when fast processes are probed by CT-CPMG experiments via simulation and show that if the intrinsic relaxation rate is not known a priori the extraction of accurate kinetics is hindered. Errors on the order of 50 % in the exchange rate are attained when processes become fast, but are minimized to 5 % with a priori information. To alleviate this shortcoming, we developed an experimental scheme probing with large amplitude spin-lock fields, which specifically contains the intrinsic proton longitudinal Eigenrelaxation rate. Our approach was validated with ubiquitin and the Oscillatoria agardhii agglutinin (OAA). For OAA, an underestimation of 66 % in the kinetic rates was observed if is not included during the analysis of CT-CPMG data and result in incorrect kinetics and imprecise amplitude information. This was overcome by combining CT-CPMG with measured with a high power R-1 rho experiment. In addition, the measurement of removes the ambiguities in choosing between different models that describe CT-CPMG data.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2013-08-152013-09
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1007/s10858-013-9769-
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of Biomolecular NMR
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 57 (1) Artikelnummer: - Start- / Endseite: 73 - 82 Identifikator: -