English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Atmospheric pressure laser ionization (APLI) coupled with Fourier transform ion cyclotron resonance mass spectrometry applied to petroleum samples analysis: comparison with electrospray ionization and atmospheric pressure photoionization methods

Panda, S. K., Brockmann, K.-J., Benter, T., & Schrader, W. (2011). Atmospheric pressure laser ionization (APLI) coupled with Fourier transform ion cyclotron resonance mass spectrometry applied to petroleum samples analysis: comparison with electrospray ionization and atmospheric pressure photoionization methods. Rapid Communications in Mass Spectrometry, 25(16), 2317-2326. doi:10.1002/rcm.5122.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Panda, Saroj K.1, Author           
Brockmann, Klaus-J.2, Author
Benter, Thorsten2, Author
Schrader, Wolfgang1, Author           
Affiliations:
1Service Department Schrader (MS), Max-Planck-Institut für Kohlenforschung, Max Planck Society, ou_1445629              
2Bergische University of Wuppertal, Department of Physical and Theoretical Chemistry, 42119 Wuppertal, Germany, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: The analysis of crude oil samples remains a tough challenge due to the complexity of the matrix and the broad range of physical and chemical properties of the various individual compounds present. In this work, atmospheric pressure laser ionization (APLI) is utilized as a complementary tool to other ionization techniques for crude oil analysis. Mass spectra obtained with electrospray ionization (ESI) and atmospheric pressure photoionization (APPI) are compared. APLI is primarily sensitive towards non-polar aromatic hydrocarbons, which are generally present in high amounts especially in heavy crude oil samples. The ionization mechanisms of APLI vs. APPI are further investigated. The results indicate the advantages of APLI over established methods like ESI and APPI. The application of APLI in combination with Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) is thus demonstrated to be a powerful tool for the analysis of aromatic species in complex crude oil fractions.

Details

show
hide
Language(s): eng - English
 Dates: 2011-06-032011-03-282011-06-032011-07-192011-08-30
 Publication Status: Issued
 Pages: 10
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1002/rcm.5122
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Rapid Communications in Mass Spectrometry
  Other : Rapid Commun. Mass Spectrom.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York, NY : John Wiley & Sons
Pages: - Volume / Issue: 25 (16) Sequence Number: - Start / End Page: 2317 - 2326 Identifier: ISSN: 0951-4198
CoNE: https://pure.mpg.de/cone/journals/resource/954925574961