English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Correction of gradient-induced phase errors in radial MRI.

Moussavi, A., Untenberger, M., Uecker, M., & Frahm, J. (2014). Correction of gradient-induced phase errors in radial MRI. Magnetic Resonance in Medicine, 71(1), 308-312. doi:10.1002/mrm.24643.

Item is

Files

show Files
hide Files
:
1900318.pdf (Publisher version), 316KB
 
File Permalink:
-
Name:
1900318.pdf
Description:
-
OA-Status:
Visibility:
Restricted (UNKNOWN id 303; )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Moussavi, A.1, Author           
Untenberger, M.1, Author           
Uecker, M.1, Author           
Frahm, J.1, Author           
Affiliations:
1Biomedical NMR Research GmbH, MPI for biophysical chemistry, Max Planck Society, ou_578634              

Content

show
hide
Free keywords: real-time MRI; eddy currents; phase errors; radial MRI
 Abstract: Purpose To correct gradient-induced phase errors in radial MRI. Methods Gradient-induced eddy currents affect the MRI data acquisition by gradient delays and phase errors that may lead to severe image artifacts for non-Cartesian imaging scenarios such as radial trajectories. While gradient delays are dealt with by respective shifts of the acquisition window during radial image acquisition, this work introduces a simple method for quantifying and correcting phase errors from the actual data prior to image reconstruction. For a given gradient system, the approach yields a specific phase error per gradient that can be used for correcting the raw data. Results Phantom studies at 9.4 T demonstrated marked improvements in radial image quality. It could be shown that the phase correction is not compromised by data undersampling. Moreover, the selective correction of gradient-induced phase errors retained the phase information caused by different concentrations of a paramagnetic contrast agent. Conclusion The proposed method does not require additional reference measurements and separately corrects for phase errors induced by eddy currents, while retaining the residual phase of the object which may carry physiologic information.

Details

show
hide
Language(s): eng - English
 Dates: 2013-02-252014-01
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1002/mrm.24643
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 71 (1) Sequence Number: - Start / End Page: 308 - 312 Identifier: ISSN: 0740-3194