  An RFQ cooler and buncher for the TRIGA-SPEC experiment

Beyer, T., Blaum, K., Block, M., Düllmann, C., Eberhardt, K., Eibach, M., et al. (2014). An RFQ cooler and buncher for the TRIGA-SPEC experiment. Applied Physics B: Lasers and Optics, 114(1-2), 129-136. doi:10.1007/s00340-013-5719-4.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:
Not specified

Creators

show
hide
 Creators:
Beyer, Thomas1, 2, Author           
Blaum, Klaus1, 2, Author           
Block, M.3, Author
Düllmann, Ch.E.3, 4, Author
Eberhardt, K.4, Author
Eibach, Martin1, 4, Author           
Frömmgen, C.4, Author
Geppert, N.4, Author
Gorges, C.4, Author
Grund, J.4, Author
Hammen, M.4, Author
Kaufmann, S.4, Author
Krieger, A.4, Author
Nagy, Szilard1, 2, Author           
Nörterhäuser, W.4, Author
Renisch, Dennis1, 4, Author           
Smorra, Christian1, Author           
Will, E.4, Author
Affiliations:
1Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society, ou_904548              
2Fakultät für Physik und Astronomie, Ruprecht-Karls-Universität, 69120 Heidelberg, Germany, ou_persistent22              
3GSI Helmholtzzentrum für Schwerionenforschung GmbH, 64291 Darmstadt, Germany, ou_persistent22              
4Institut für Kernchemie, Johannes Gutenberg-Universität, 55128 Mainz, Germany, ou_persistent22              

Content

show
hide
Free keywords: -
 MPINP: Speichertechnik - Abteilung Blaum
 MPINP: Expt. TRIGATRAP - Abteilung Blaum
 Abstract: A linear Paul trap for cooling of ion beams, the former cooler for emittance elimination radiofrequency quadrupole (RFQ) at MISTRAL/ISOLDE, has been installed and commissioned at the TRIGA-SPEC experiment located at the research reactor TRIGA Mainz. It is connected to a hot-surface-ionization ion source and a subsequent mass separator for ionization and pre-separation of neutron-rich fission products as delivered from the reactor. The capability of accumulating and bunching ion beams has been implemented to provide low-emittance ion pulses of 250 ns width containing up to 106 ions. A technical description of the upgraded RFQ as well as its characterization with stable ions is presented. Its installation allows delivery of low-emittance ion bunches to the two branches of the TRIGA-SPEC experiment, namely TRIGA-TRAP and TRIGA-LASER.

Details

show
hide
Language(s): eng - English
 Dates: 2014-01-01
 Publication Status: Issued
 Pages: 8
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1007/s00340-013-5719-4
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Applied Physics B: Lasers and Optics
  Other : Appl. Phys. B: Lasers O.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Heidelberg : Springer-Verlag
Pages: - Volume / Issue: 114 (1-2) Sequence Number: - Start / End Page: 129 - 136 Identifier: ISSN: 0946-2171
CoNE: https://pure.mpg.de/cone/journals/resource/954928582870