Deutsch
 
Benutzerhandbuch Datenschutzhinweis Impressum Kontakt
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Quantum noise in laser-interferometer gravitational-wave detectors with a heterodyne readout scheme

Buonanno, A., Chen, Y., & Mavalvala, N. (2003). Quantum noise in laser-interferometer gravitational-wave detectors with a heterodyne readout scheme. Physical Review D, 67: 122005. doi:10.1103/PhysRevD.67.122005.

Item is

Basisdaten

einblenden: ausblenden:
Datensatz-Permalink: http://hdl.handle.net/11858/00-001M-0000-0018-DA9D-A Versions-Permalink: http://hdl.handle.net/11858/00-001M-0000-0018-DAA0-D
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
gr-qc_0302041.pdf (Preprint), 384KB
Name:
gr-qc_0302041.pdf
Beschreibung:
File downloaded from arXiv at 2014-04-10 14:36
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
:
PhysRevD.67.122005.pdf (beliebiger Volltext), 723KB
Name:
PhysRevD.67.122005.pdf
Beschreibung:
-
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Buonanno, Alessandra1, 2, Autor              
Chen, Yanbei, Autor
Mavalvala, Nergis, Autor
Affiliations:
1Gravitation et Cosmologie (GReCO), Institut d’Astrophysique de Paris (CNRS), ou_persistent22              
2Astrophysical and Cosmological Relativity, AEI-Golm, MPI for Gravitational Physics, Max Planck Society, ou_1933290              

Inhalt

einblenden:
ausblenden:
Schlagwörter: General Relativity and Quantum Cosmology, gr-qc
 Zusammenfassung: We analyze and discuss the quantum noise in signal-recycled laser interferometer gravitational-wave detectors, such as Advanced LIGO, using a heterodyne readout scheme and taking into account the optomechanical dynamics. Contrary to homodyne detection, a heterodyne readout scheme can simultaneously measure more than one quadrature of the output field, providing an additional way of optimizing the interferometer sensitivity, but at the price of additional noise. Our analysis provides the framework needed to evaluate whether a homodyne or heterodyne readout scheme is more optimal for second generation interferometers from an astrophysical point of view. As a more theoretical outcome of our analysis, we show that as a consequence of the Heisenberg uncertainty principle the heterodyne scheme cannot convert conventional interferometers into (broadband) quantum non-demolition interferometers.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2003-02-112003
 Publikationsstatus: Im Druck publiziert
 Seiten: 16 pages, 8 figures
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: arXiv: gr-qc/0302041
DOI: 10.1103/PhysRevD.67.122005
URI: http://arxiv.org/abs/gr-qc/0302041
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Physical Review D
  Andere : Phys. Rev. D.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Lancaster, Pa. : American Physical Society
Seiten: - Band / Heft: 67 Artikelnummer: 122005 Start- / Endseite: - Identifikator: ISSN: 0556-2821
CoNE: /journals/resource/111088197762258