English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Temporal Jitter of the BOLD Signal Reveals a Reliable Initial Dip and Improved Spatial Resolution

Watanabe, M., Bartels, A., Macke, J., Murayama, Y., & Logothetis, N. (2013). Temporal Jitter of the BOLD Signal Reveals a Reliable Initial Dip and Improved Spatial Resolution. Current Biology, 23(21), 2146-2150. doi:10.1016/j.cub.2013.08.057.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:
Not specified

Creators

show
hide
 Creators:
Watanabe, M1, Author           
Bartels, A1, Author           
Macke, JH2, Author           
Murayama, Y1, Author           
Logothetis, NK1, Author           
Affiliations:
1Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497798              
2Research Group Computational Vision and Neuroscience, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497805              

Content

show
hide
Free keywords: -
 Abstract: fMRI, one of the most important noninvasive brain imaging methods, relies on the blood oxygen level-dependent (BOLD) signal, whose precise underpinnings are still not fully understood [1]. It is a widespread assumption that the components of the hemodynamic response function (HRF) are fixed relative to each other in time, leading most studies as well as analysis tools to focus on trial-averaged responses, thus using or estimating a condition- or location-specific “canonical HRF” [2, 3 and 4]. In the current study, we examined the nature of the variability of the BOLD response and asked in particular whether the positive BOLD peak is subject to trial-to-trial temporal jitter. Our results show that the positive peak of the stimulus-evoked BOLD signal exhibits a trial-to-trial temporal jitter on the order of seconds. Moreover, the trial-to-trial variability can be exploited to uncover the initial dip in the majority of voxels by pooling trial responses with large peak latencies. Initial dips exposed by this procedure possess higher spatial resolution compared to the positive BOLD signal in the human visual cortex. These findings allow for the reliable observation of fMRI signals that are physiologically closer to neural activity, leading to improvements in both temporal and spatial resolution.

Details

show
hide
Language(s):
 Dates: 2013-11
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1016/j.cub.2013.08.057
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Current Biology
  Abbreviation : Curr. Biol.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: London, UK : Cell Press
Pages: - Volume / Issue: 23 (21) Sequence Number: - Start / End Page: 2146 - 2150 Identifier: ISSN: 0960-9822
CoNE: https://pure.mpg.de/cone/journals/resource/954925579107