  Functional QSM at 9.4T with single echo gradient-echo and EPI acquisition

Balla, D., Ehses, P., Pohmann, R., Budde, J., Mirkes, C., Shajan, G., et al. (2013). Functional QSM at 9.4T with single echo gradient-echo and EPI acquisition. In 2nd International Workshop on MRI Phase Contrast & Quantitative Susceptibility Mapping (QSM 2013) (pp. 1-4).

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
Balla_fQSM_9T_extended_abstract.pdf (beliebiger Volltext), 573KB
Name:
Balla_fQSM_9T_extended_abstract.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
http://weill.cornell.edu/mri/QSM13/index.html (Inhaltsverzeichnis)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Balla, DZ1, 2, Autor           
Ehses, P1, 2, Autor           
Pohmann, R1, 2, Autor           
Budde, J1, 2, Autor           
Mirkes, C1, 2, Autor           
Shajan, G1, 2, Autor           
Bowtell, R, Autor
Scheffler, K1, 2, Autor           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Functional quantitative susceptibility mapping was performed on high resolution time-series acquired at 9.4T. Two alternative pulse sequences, two functional stimulation paradigms and three susceptibility mapping pipelines were evaluated. In addition to the conventional statistical parametric mapping of brain activation, also multivariate processing was performed in order to investigate the effect of physiological variations on the signal, and to learn about possible differences between these effects in the evolution of signal modulus and the evolution of calculated susceptibilities. The results provide useful information on the potential and the technical limitations of functional quantitative susceptibility mapping at 9.4T.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2013-07
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: BibTex Citekey: BallaEPBMSBS2013_2
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 2nd International Workshop on MRI Phase Contrast Quantitative Susceptibility Mapping (QSM 2013)
Veranstaltungsort: Ithaca, NY, USA
Start-/Enddatum: -

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: 2nd International Workshop on MRI Phase Contrast & Quantitative Susceptibility Mapping (QSM 2013)
Genre der Quelle: Konferenzband
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: - Artikelnummer: - Start- / Endseite: 1 - 4 Identifikator: -