  The cryogenic gas stopping cell of SHIPTRAP

Droese, C., Eliseev, S., Blaum, K., Block, M., Herfurth, F., Laatiaoui, M., Lautenschläger, F., Minaya Ramirez, E., Schweikhard, L., Simon, V., & Thirolf, P. (2014). The cryogenic gas stopping cell of SHIPTRAP. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 338, 126-138. doi:10.1016/j.nimb.2014.08.004.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:
非表示:
説明:
-
OA-Status:

作成者

表示:
非表示:
 作成者:
Droese, C.1, 2, 著者
Eliseev, Sergey3, 著者           
Blaum, Klaus3, 著者           
Block, M.4, 著者
Herfurth, F.4, 著者
Laatiaoui, M.2, 著者
Lautenschläger, F.5, 著者
Minaya Ramirez, Enrique2, 3, 著者           
Schweikhard, L.1, 著者
Simon, V.V.2, 著者
Thirolf, P.G.6, 著者
所属:
1Ernst-Moritz-Arndt-Universität, Felix-Hausdorff-Straße 6, 17489 Greifswald, Germany, ou_persistent22              
2Helmholtz-Institut Mainz, Johannes Gutenberg-Universität, 55099 Mainz, Germany, ou_persistent22              
3Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society, ou_904548              
4GSI Helmholtzzentrum für Schwerionenforschung, Planckstraße 1, 64291 Darmstadt, Germany, ou_persistent22              
5Technische Universität Darmstadt, Pankratiusstraße 2, 64289 Darmstadt, Germany, ou_persistent22              
6Ludwig Maximilians-Universität München, Am Coulombwall 1, 85748 Garching, Germany, ou_persistent22              

内容説明

表示:
非表示:
キーワード: -
 MPINP: Speichertechnik - Abteilung Blaum
 要旨: The overall efficiency of the Penning-trap mass spectrometer SHIPTRAP at GSI Darmstadt, employed for high-precision mass measurements of exotic nuclei in the mass region above fermium, is presently mostly limited by the stopping and extraction of fusion-evaporation products in the SHIPTRAP gas cell. To overcome this limitation a second-generation gas cell with increased stopping volume was designed. In addition, its operation at cryogenic temperatures leads to a higher gas density at a given pressure and an improved cleanliness of the helium buffer gas. Here, the results of experiments with a 219Rn recoil ion source are presented. An extraction efficiency of 74(3)% was obtained, a significant increase compared to the extraction efficiency of 30% of the present gas stopping cell operated at room temperature. The optimization of electric fields and other operating parameters at room as well as cryogenic temperatures is described in detail. Furthermore, the extraction time of 219Rn ions was determined for several operating parameters.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2014-09-07
 出版の状態: オンラインで出版済み
 ページ: 13
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): DOI: 10.1016/j.nimb.2014.08.004
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
  省略形 : NIM B
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Amsterdam : Elsevier B.V.
ページ: - 巻号: 338 通巻号: - 開始・終了ページ: 126 - 138 識別子(ISBN, ISSN, DOIなど): ISSN: 0168-583X
CoNE: https://pure.mpg.de/cone/journals/resource/954925484704