English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  X-ray-optical cross-correlator for gas-phase experiments at the Linac Coherent Light Source free-electron laser

Schorb, S., Gorkhover, T., Cryan, J. P., Glownia, J. M., Bionta, M. R., Coffee, R. N., et al. (2012). X-ray-optical cross-correlator for gas-phase experiments at the Linac Coherent Light Source free-electron laser. Applied Physics Letters, 100(12): 121107, pp. 1-4. doi:10.1063/1.3694935.

Item is

Basic

show hide
Genre: Journal Article
Alternative Title : X-ray-optical cross-correlator for gas-phase experiments at the Linac Coherent Light Source free-electron laser

Files

show Files
hide Files
:
ApplPhysLett_100_2012_121107_1.pdf (Any fulltext), 2MB
 
File Permalink:
-
Name:
ApplPhysLett_100_2012_121107_1.pdf
Description:
-
OA-Status:
Visibility:
Restricted (Max Planck Institute for Medical Research, MHMF; )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show
hide
Locator:
http://dx.doi.org/10.1063/1.3695163 (Any fulltext)
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Schorb, Sebastian, Author
Gorkhover, Tais, Author
Cryan, James P., Author
Glownia, James M., Author
Bionta, M. R., Author
Coffee, Ryan N., Author
Erk, Benjamin1, Author           
Boll, Rebecca, Author
Schmidt, Carlo, Author
Rolles, Daniel1, Author           
Rudenko, Artem, Author
Rouzee, Arnaud, Author
Swiggers, Michelle L., Author
Carron, S., Author
Castagna, Jean-Charles, Author
Bozek, John D., Author
Messerschmidt, Marc, Author
Schlotter, William F., Author
Bostedt, Christoph, Author
Affiliations:
1Department of Biomolecular Mechanisms, Max Planck Institute for Medical Research, Max Planck Society, ou_1497700              

Content

show
hide
Free keywords: -
 Abstract: X−ray−optical pump−probe experiments at the Linac Coherent Light Source (LCLS) have so far been limited to a time resolution of 280 fs fwhm due to timing jitter between the accelerator−based free−electron laser (FEL) and optical lasers. We have implemented a single−shot cross−correlator for femtosecond x−ray and infrared pulses. A reference experiment relying only on the pulse arrival time information from the cross−correlator shows a time resolution better than 50 fs fwhm (22 fs rms) and also yields a direct measurement of the maximal x−ray pulse length. The improved time resolution enables ultrafast pump−probe experiments with x−ray pulses from LCLS and other FEL sources

Details

show
hide
Language(s): eng - English
 Dates: 2012-01-052012-01-262012-03-19
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Applied Physics Letters
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Melville, NY : American Institute of Physics
Pages: - Volume / Issue: 100 (12) Sequence Number: 121107 Start / End Page: 1 - 4 Identifier: Other: 0003-6951
CoNE: https://pure.mpg.de/cone/journals/resource/954922836223