Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  A low power radiofrequency pulse for simultaneous multislice excitation and refocusing

Eichner, C., Wald, L. L., & Setsompop, K. (2014). A low power radiofrequency pulse for simultaneous multislice excitation and refocusing. Magnetic Resonance in Medicine, 72(4), 949-958. doi:10.1002/mrm.25389.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Eichner, Cornelius1, 2, Autor           
Wald, Lawrence L.2, Autor
Setsompop, Kawin2, Autor
Affiliations:
1Department Neurophysics, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634550              
2Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: SMS; blipped CAIPI; Multiband; PINS; RF pulse design
 Zusammenfassung: Purpose: Simultaneous multislice (SMS) acquisition enables increased temporal efficiency of MRI. Nonetheless, MultiBand (MB) radiofrequency (RF) pulses used for SMS can cause large energy deposition. Power independent of number of slices (PINS) pulses reduce RF power at cost of reduced bandwidth and increased off-resonance dependency. This work improves PINS design to further reduce energy deposition, off-resonance dependency and peak power.

Theory and Methods: Modifying the shape of MB RF-pulses allows for mixing with PINS excitation, creating a new pulse type with reduced energy deposition and SMS excitation characteristics. Bloch Simulations were used to evaluate excitation and off-resonance behavior of this MultiPINS pulse. In this work, MultiPINS was used for whole-brain MB=3 acquisition of high angular and spatial resolution diffusion MRI at 7 Tesla in 3 min.

Results: By using MultiPINS, energy transmission and peak power for SMS imaging can be significantly reduced compared with PINS and MB pulses. For MB=3 acquisition in this work, MultiPINS reduces energy transmission by up to approximate to 50% compared with PINS pulses. The energy reduction was traded off to shorten the MultiPINS pulse, yielding higher signal at off-resonances for spin-echo acquisitions.

Conclusion: MB and PINS pulses can be combined to enable low energy and peak power SMS acquisition.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2014-07-082014-01-202014-07-082014-08-072014-10
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1002/mrm.25389
PMID: 25103999
Anderer: Epub 2014
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York : Wiley-Liss
Seiten: - Band / Heft: 72 (4) Artikelnummer: - Start- / Endseite: 949 - 958 Identifikator: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149