English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Impact of laser excitation intensity on deep UV fluorescence detection in microchip electrophoresis

Schulze, P., Ludwig, M., & Belder, D. (2008). Impact of laser excitation intensity on deep UV fluorescence detection in microchip electrophoresis. Electrophoresis, 29(24), 4894-4899. doi:10.1002/elps.200800179.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Schulze, P.1, 2, Author           
Ludwig, M.1, 3, Author
Belder, D.1, 3, Author           
Affiliations:
1Institute of Analytical Chemistry, University of Leipzig, Leipzig, Germany, ou_persistent22              
2Service Department Schulze (GC, HPLC), Max-Planck-Institut für Kohlenforschung, Max Planck Society, ou_1445630              
3Research Group Belder, Max-Planck-Institut für Kohlenforschung, Max Planck Society, ou_1445595              

Content

show
hide
Free keywords: Deep UV excitation; LIF; MCE; Native fluorescence detection; Protein
 Abstract: A high intensity 266 nm continuous wave (cw-) laser developed for material processing was utilised as an excitation source for sensitive native fluorescence detection of unlabelled compounds in MCE. This 120 mW laser was attached via an optical fibre into a commercial epifluorescence microscope. With this MCE set-up we evaluated the impact of laser power on the S/N of aromatic compounds as well as of proteins. Compared with a previous work which used a 4 mW pulsed laser for excitation, improved S/N for small aromatics and to a lesser extent for proteins could be attained. The LOD of the system was determined down to 24 ng/mL for serotonin (113 nM), 24 ng/mL for propranolol (81 nM), 80 ng/mL for tryptophan (392 nM) and 80 ng/mL for an aromatic diol (475 nM). Sensitive protein detection was obtained at concentrations of 5 μg/mL for lysocyme, trypsinogen and chymotrypsinogen (340, 208 and 195 nM, respectively). Finally, a comparison of the cw- with a pulsed 266 nm laser, operating at the same average power, showed a higher attainable sensitivity of the cw-laser. This can be attributed to fluorescence saturation and photobleaching effects of the pulsed laser at high pulse energies.

Details

show
hide
Language(s): eng - English
 Dates: 2008-11-242008-12
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1002/elps.200800179
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Electrophoresis
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Weinheim, Germany : Verlag Chemie
Pages: - Volume / Issue: 29 (24) Sequence Number: - Start / End Page: 4894 - 4899 Identifier: ISSN: 0173-0835
CoNE: https://pure.mpg.de/cone/journals/resource/954925486765