  Test–retest reliability of the novel 5-HT1B receptor PET radioligand [11C]P943

Saricicek, A., Chen, J., Planeta, B., Ruf, B., Subramanyam, K., Maloney, K., et al. (2015). Test–retest reliability of the novel 5-HT1B receptor PET radioligand [11C]P943. European Journal of Nuclear Medicine and Molecular Imaging, 42(3), 468-477. doi:10.1007/s00259-014-2958-5.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Saricicek, Aybala1, 2, 3, Autor
Chen, Jason1, Autor
Planeta, Beata4, Autor
Ruf, Barbara1, Autor
Subramanyam, Kalyani1, 2, Autor
Maloney, Kathleen1, 2, Autor
Matuskey, David1, 2, 4, Autor
Labaree, David4, Autor
Deserno, Lorenz5, 6, Autor           
Neumeister, Alexander1, 7, 8, Autor
Krystal, John H.1, 2, 8, Autor
Gallezot, Jean-Dominique4, Autor
Huang, Yiyun4, Autor
Carson, Richard E.2, Autor
Bhagwagar, Zubin1, 2, 9, Autor
Affiliations:
1Department of Psychiatry, Yale University, New Haven, CT, USA, ou_persistent22              
2Abraham Ribicoff Research Facilities, Connecticut Mental Health Center, New Haven, CT, USA, ou_persistent22              
3Department of Psychiatry, Izmir Katip Celebi University, Turkey , ou_persistent22              
4PET Center, Department of Diagnostic Radiology, Yale University, New Haven, CT, USA, ou_persistent22              
5Department of Psychiatry and Psychotherapy, Charité University Medicine Berlin, Germany, ou_persistent22              
6Max Planck Fellow Group Cognitive and Affective Control of Behavioural Adaptation, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_1753350              
7Department of Psychiatry, Icahn School of Medicine at Mount Sinai, New York, NY, USA, ou_persistent22              
8Clinical Neuroscience Division, National Center for PTSD, West Haven, CT, USA, ou_persistent22              
9Bristol-Myers Squibb, Wallingford, CT, USA, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Serotonin; 5-HT1B; Positron emission tomography; Graphical analysis
 Zusammenfassung: [11C]P943 is a novel, highly selective 5-HT1B PET radioligand. The aim of this study was to determine the test–retest reliability of [11C]P943 using two different modeling methods and to perform a power analysis with each quantification technique.
Methods

Seven healthy volunteers underwent two PET scans on the same day. Regions of interest (ROIs) were the amygdala, hippocampus, pallidum, putamen, insula, frontal, anterior cingulate, parietal, temporal and occipital cortices, and cerebellum. Two multilinear radioligand quantification techniques were used to estimate binding potential: MA1, using arterial input function data, and the second version of the multilinear reference tissue model analysis (MRTM2), using the cerebellum as the reference region. Between-scan percent variability and intraclass correlation coefficients (ICC) were used to assess test–retest reliability. We also performed power analyses to determine the method that would allow the least number of subjects using within-subject or between-subject study designs. A voxel-wise ICC analysis for MRTM2 BPND was performed for the whole brain and all the ROIs studied.
Results

Mean percent variability between two scans across regions ranged between 0.4 % and 12.4 % for MA1 BPND, 0.5 % and 11.5 % for MA1 BPP, 16.7 % and 28.3 % for MA1 BPF, and between 0.2 % and 5.4 % for MRTM2 BPND. The power analyses showed a greater number of subjects were required using MA1 BPF compared with other outcome measures for both within-subject and between-subject study designs. ICC values were the highest using MRTM2 BPND and the lowest with MA1 BPF in ten ROIs. Small regions and regions with low binding had lower ICC values than large regions and regions with high binding.
Conclusion

Reliable measures of 5-HT1B receptor binding can be obtained using the novel PET radioligand [11C]P943. Quantification of 5-HT1B receptor binding with MRTM2 BPND and with MA1 BPP provided the least variability and optimal power for within-subject and between-subject designs.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2014-03-032014-11-032014-11-272015-03
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1007/s00259-014-2958-5
PMID: 25427881
Anderer: Epub 2014
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: European Journal of Nuclear Medicine and Molecular Imaging
  Andere : Eur. J. Nucl. Med. Mol. Imaging
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Heidelberg, Germany : Springer-Verlag
Seiten: - Band / Heft: 42 (3) Artikelnummer: - Start- / Endseite: 468 - 477 Identifikator: ISSN: 1619-7070
CoNE: https://pure.mpg.de/cone/journals/resource/954925519624