Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Practical aspects of Boersch phase contrast electron microscopy of biological specimens

Walter, A., Muzik, H., Vieker, H., Turchanin, A., Beyer, A., Gölzhäuser, A., et al. (2012). Practical aspects of Boersch phase contrast electron microscopy of biological specimens. Ultramicroscopy, 116, 62-72.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Walter, Andreas1, Autor           
Muzik, Heiko, Autor
Vieker, Henning, Autor
Turchanin, Andrey, Autor
Beyer, André, Autor
Gölzhäuser, Armin, Autor
Lacher, Manfred, Autor
Steltenkamp, Siegfried, Autor
Schmitz, Sam, Autor
Holik, Peter, Autor
Kühlbrandt, Werner1, Autor           
Rhinow, Daniel1, Autor           
Affiliations:
1Department of Structural Biology, Max Planck Institute of Biophysics, Max Planck Society, ou_2068291              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Phase plate; Transmission electronmicroscopy; Aberration correction; X-ray photoelectron spectroscopy; Auger electron spectroscopy; Helium ion microscopy
 Zusammenfassung: Implementation of physical phase plates into transmission electron microscopes to achieve in-focus contrast for ice-embedded biologicalspecimens poses several technological challenges. During the last decade several phase plates designs have been introduced and tested for electron cryo-microscopy (cryoEM), including thin film (Zernike) phase plates and electrostatic devices. Boerschphase plates (BPPs) are electrostatic einzel lenses shifting the phase of the unscattered beam by an arbitrary angle. Adjusting the phase shift to 90° achieves the maximum contrast transfer for phase objects such as biomolecules. Recently, we reported the implementation of a BPP into a dedicated phasecontrast aberration-corrected electron microscope (PACEM) and demonstrated its use to generate in-focus contrast of frozen–hydrated specimens. However, a number of obstacles need to be overcome before BPPs can be used routinely, mostly related to the phase plate devices themselves. CryoEM with a physical phase plate is affected by electrostatic charging, obliteration of low spatial frequencies, and mechanical drift. Furthermore, BPPs introduce single sideband contrast (SSB), due to the obstruction of Friedel mates in the diffraction pattern. In this study we address the technical obstacles in detail and show how they may be overcome. We use X-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES) to identify contaminants responsible for electrostatic charging, which occurs with most phase plates. We demonstrate that obstruction of low-resolution features is significantly reduced by lowering the acceleration voltage of the microscope. Finally, we present computational approaches to correct BPP images for SSB contrast and to compensate for mechanical drift of the BPP.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2012
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: eDoc: 609616
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Ultramicroscopy
  Alternativer Titel : Ultramicr.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 116 Artikelnummer: - Start- / Endseite: 62 - 72 Identifikator: -