English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Practical aspects of Boersch phase contrast electron microscopy of biological specimens

Walter, A., Muzik, H., Vieker, H., Turchanin, A., Beyer, A., Gölzhäuser, A., et al. (2012). Practical aspects of Boersch phase contrast electron microscopy of biological specimens. Ultramicroscopy, 116, 62-72. doi:10.1016/j.ultramic.2012.03.009.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Walter, Andreas1, Author           
Muzik, Heiko2, Author
Vieker, Henning2, Author
Turchanin, Andrey2, Author
Beyer, André2, Author
Gölzhäuser, Armin2, Author
Lacher, Manfred2, Author
Steltenkamp, Siegfried2, Author
Schmitz, Sam2, Author
Holik, Peter2, Author
Kühlbrandt, Werner1, Author                 
Rhinow, Daniel1, Author           
Affiliations:
1Department of Structural Biology, Max Planck Institute of Biophysics, Max Planck Society, ou_2068291              
2External Organizations, ou_persistent22              

Content

show
hide
Free keywords: Phase plate; Transmission electronmicroscopy; Aberration correction; X-ray photoelectron spectroscopy; Auger electron spectroscopy; Helium ion microscopy
 Abstract: Implementation of physical phase plates into transmission electron microscopes to achieve in-focus contrast for ice-embedded biologicalspecimens poses several technological challenges. During the last decade several phase plates designs have been introduced and tested for electron cryo-microscopy (cryoEM), including thin film (Zernike) phase plates and electrostatic devices. Boerschphase plates (BPPs) are electrostatic einzel lenses shifting the phase of the unscattered beam by an arbitrary angle. Adjusting the phase shift to 90° achieves the maximum contrast transfer for phase objects such as biomolecules. Recently, we reported the implementation of a BPP into a dedicated phasecontrast aberration-corrected electron microscope (PACEM) and demonstrated its use to generate in-focus contrast of frozen–hydrated specimens. However, a number of obstacles need to be overcome before BPPs can be used routinely, mostly related to the phase plate devices themselves. CryoEM with a physical phase plate is affected by electrostatic charging, obliteration of low spatial frequencies, and mechanical drift. Furthermore, BPPs introduce single sideband contrast (SSB), due to the obstruction of Friedel mates in the diffraction pattern. In this study we address the technical obstacles in detail and show how they may be overcome. We use X-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES) to identify contaminants responsible for electrostatic charging, which occurs with most phase plates. We demonstrate that obstruction of low-resolution features is significantly reduced by lowering the acceleration voltage of the microscope. Finally, we present computational approaches to correct BPP images for SSB contrast and to compensate for mechanical drift of the BPP.

Details

show
hide
Language(s): eng - English
 Dates: 2012-03-172012-05
 Publication Status: Issued
 Pages: 11
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: eDoc: 609616
DOI: 10.1016/j.ultramic.2012.03.009
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Ultramicroscopy
  Abbreviation : Ultramicroscopy
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Amsterdam : Elsevier
Pages: - Volume / Issue: 116 Sequence Number: - Start / End Page: 62 - 72 Identifier: ISSN: 0304-3991
CoNE: https://pure.mpg.de/cone/journals/resource/954925512451