  The Fddd four-circle diffractometer for single-crystal X-ray studies at temperatures down to 9 K

Copley, R., Goeta, A., Lehmann, C. W., Cole, J., Yufit, D., Howard, J., & Archer, J. (1997). The Fddd four-circle diffractometer for single-crystal X-ray studies at temperatures down to 9 K. Journal of Applied Crystallography, 30, 413-417. doi:10.1107/S0021889897002525.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Copley, R.C.B.1, 著者
Goeta, A.E.1, 著者
Lehmann, C. W.1, 2, 著者           
Cole, J.C.1, 著者
Yufit, D.S.1, 著者
Howard, J.A.K.1, 著者
Archer, J.M.3, 著者
所属:
1Department of Chemistry, University of Durham, South Road, Durham DH1 3LE, England,, ou_persistent22              
2Service Department Lehmann (EMR), Max-Planck-Institut für Kohlenforschung, Max Planck Society, ou_1445625              
3lnstitut Max von Laue Paul Langevin, F-38042 Grenoble, France. E-mail: j.a.k.howard@durham.ac.uk, ou_persistent22              

内容説明

表示:
非表示:
キーワード: -
 要旨: The Fddd four-circle diffractometer system has been developed to perform X-ray diffraction experiments at temperatures as low as 9 K. The diffractometer consists of: (i) a Siemens rotating-anode generator; (ii) a Huber goniometer with offset X circle; (iii) a Siemens Fast Scintillation Detector; and (iv) an APD `202' Displex cryogenic refrigerator. The belt-driven rotating anode gives an X-ray flux that is far in excess of that obtained from a sealed X-ray tube and leads to faster data collections and the opportunity to study smaller samples. X-ray beam alignment requires precise movements of the 300 kg goniometer and this is achieved using compressed air pads. Steel-braided gas lines that allow the transfer of helium gas between the Displex and the compressor are supported by a counterbalance system. The stress on these lines has been reduced by attaching them to the Displex via high-pressure rotating joints and by passing them through a metal ring that is attached to the circle. A compact vacuum gauge has been mounted through one of the four ports on the top of the cryostat and gives valuable information on the pressure within the Displex sample chamber during an experiment. Crystals are mounted on sharpened 0.3 mm graphite pencil leads that are held in a newly designed sample mount. The temperature reported from the second stage of the Displex has been assessed by consideration of temperature standards that include the solid-state phase transitions of benzil (1,2-diphenylethanedione) and terbium vanadate.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 1997
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): DOI: 10.1107/S0021889897002525
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Journal of Applied Crystallography
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Oxford, England : Blackwell Publishing on behalf of the International Union of Crystallography
ページ: - 巻号: 30 通巻号: - 開始・終了ページ: 413 - 417 識別子(ISBN, ISSN, DOIなど): ISSN: 0021-8898